switch the battery OFF when:
Not operating the machine for more than one month.
Maintaining the electrical system.
Disposing of the battery.
Replacing the fuse and/or fuse link.
Connecting the auxiliary cables.
NOTE: Disconnect the operation of the accumulator jar switch one
minute later after the engine is turned off.
Caution! To avoid damaging the electrical system, do not turn off the
battery while the engine is still running.
NOTE:
After disconnecting the accumulator jar switch, the whole
electrical system will be cut off.
This may delete the radio's stored data set. Reset the data in
case that this happens.
Cut off the power supply from the storage battery to the machine's
electrical system.
this switch is located under the pedal base, which is nearby the
NOTE:
main valve
.
(O) (="OFF"-position): Cuts off the electric current. Keep the switch at
a free sagging state while in this position.
(I): (="ON"-position): Electric current is flowing through the circuit.
Make sure the switch is turned on before starting the engine.