HEX
DESCRIPTION
ADDRESS
Positive VARs, 3-Ph,
0C2F
- 0C30
Maximum Avg Demand
Negative Watts, 3-Ph,
0C31
- 0C32
Maximum Avg Demand
Negative VARs, 3-Ph,
0C33
- 0C34
Maximum Avg Demand
VAs, 3-Ph, Maximum Avg
0C35
- 0C36
Demand
Positive Power Factor, 3-
0C37
- 0C38
Ph, Maximum Avg
Demand
Negative Power Factor, 3-
0C39
- 0C3A
Ph, Maximum Avg
Demand
0C3B - 0C3C Frequency, Maximum
7, 13
THD Block
0F9F
- 0F9F
Volts A-N, %THD
0FA0
- 0FA0
Volts B-N, %THD
0FA1
- 0FA1
Volts C-N, %THD
0FA2
- 0FA2
Amps A, %THD
0FA3
- 0FA3
Amps B, %THD
0FA4
- 0FA4
Amps C, %THD
Phase A Current 0th
0FA5
- 0FA5
harmonic magnitude
Phase A Current 1st
0FA6
- 0FA6
harmonic magnitude
Phase A Current 2nd
0FA7
- 0FA7
harmonic magnitude
Phase A Current 3rd
0FA8
- 0FA8
harmonic magnitude
Phase A Current 4th
0FA9
- 0FA9
harmonic magnitude
Phase A Current 5th
0FAA
- 0FAA
harmonic magnitude
Phase A Current 6th
0FAB
- 0FAB
harmonic magnitude
Phase A Current 7th
0FAC
- 0FAC
harmonic magnitude
Phase A Voltage 0th
0FAD - 0FAD
harmonic magnitude
Phase A Voltage 1st
0FAE
- 0FAE
harmonic magnitude
Phase A Voltage 2nd
0FAF
- 0FAF
harmonic magnitude
Phase A Voltage 3rd
0FB0
- 0FB0
harmonic magnitude
Phase B Current
0FB1
- 0FB8
Phase B Voltage
0FB9
- 0FBC
Phase C Current
0FBD - 0FC4
Phase C Voltage
0FC5
- 0FC8
14
Phase Angle Block
1003
- 1003
Phase A Current
1004
- 1004
Phase B Current
1005
- 1005
Phase C Current
1006
- 1006
Angle, Volts A-B
1007
- 1007
Angle, Volts B-C
1008
- 1008
Angle, Volts C-A
5–4
1
FORMAT
RANGE
FLOAT
0 to +9999 M
FLOAT
0 to +9999 M
FLOAT
0 to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-1.00 to +1.00
FLOAT
-1.00 to +1.00
FLOAT
0 to 65.00
UINT16
0 to 9999, or 65535
UINT16
0 to 9999, or 65535
UINT16
0 to 9999, or 65535
UINT16
0 to 9999, or 65535
UINT16
0 to 9999, or 65535
UINT16
0 to 9999, or 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
UINT16
0 to 65535
same as Phase A Current 0th to 7th harmonic magnitudes
same as Phase A Voltage 0th to 3rd harmonic magnitudes
same as Phase A Current 0th to 7th harmonic magnitudes
same as Phase A Voltage 0th to 3rd harmonic magnitudes
SINT16
-1800 to +1800
SINT16
-1800 to +1800
SINT16
-1800 to +1800
SINT16
-1800 to +1800
SINT16
-1800 to +1800
SINT16
-1800 to +1800
UNITS OR
6
RESOLUTION
VARs
watts
VARs
VAs
none
none
Hz
Block Size:
read-only
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
none
none
none
none
none
none
none
none
none
none
none
none
Block Size:
read-only
0.1 degree
0.1 degree
0.1 degree
0.1 degree
0.1 degree
0.1 degree
Block Size:
EPM 6000 MULTI-FUNCTION POWER METERING SYSTEM – USER GUIDE
CHAPTER 5: COMMUNICATIONS
COMMENTS
# REG
2
2
2
2
2
2
2
34
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8
4
8
4
42
1
1
1
1
1
1
6