Download Print this page

Cisco NCS1004 Manual page 9

Configuring controllers
Hide thumbs Also See for NCS1004:

Advertisement

Configuring Controllers
Transceiver Temperature : 27 Celsius
AINS Soak
AINS Timer
AINS remaining time
To override the default AINS settings on a specific controller, use the following commands:
automatic-in-service controller optics R/S/I/P hours hours minutes minutes
Note
This configuration does not persist after a RP reload operation.
The following is a sample in which the optics controller on the OTN-XP card is configured with a soak time
period of 45 minutes.
RP/0/RP0/CPU0:ios#automatic-in-service controller optics 0/1/0/0 hours 0 minutes 45
Tue Apr 28 11:55:15.666 UTC
RP/0/RP0/CPU0:ios#show controllers optics 0/1/0/0
Tue Apr 28 11:55:30.323 UTC
Controller State: Down
Transport Admin State: Automatic In Service
Laser State: On
LED State: Red
Optics Status
Ethernet Compliance Code: 100GBASE-LR4
: Pending
: 0h, 2m
: 120 seconds
Optics Type:
100G QSFP28 LR4
Alarm Status:
-------------
Detected Alarms: None
LOS/LOL/Fault Status:
Alarm Statistics:
-------------
HIGH-RX-PWR = 0
HIGH-TX-PWR = 0
HIGH-LBC = 0
OOR-CD = 0
WVL-OOL = 0
IMPROPER-REM = 0
TX-POWER-PROV-MISMATCH = 0
Performance Monitoring: Enable
THRESHOLD VALUES
----------------
Parameter
LOW-RX-PWR = 0
LOW-TX-PWR = 0
HIGH-DGD = 0
OSNR = 0
MEA
= 0
High Alarm
Low Alarm
High Warning
Configuring AINS on OTN-XP Card
Low Warning
Configuring Controllers