Protection Features - GE Multilin 745 Instruction Manual

Transformer management relay
Table of Contents

Advertisement

Transformer Management Relay

Protection Features

Symbol
Common Protection Element
59/81-1
Volts-Per-Hertz 1
59/81-2
Volts-Per-Hertz 2
81U-1
Underfrequency 1
81U-2
Underfrequency 2
81U-R1
Frequency Decay Rate 1
81U-R2
Frequency Decay Rate 2
81U-R3
Frequency Decay Rate 3
81U-R4
Frequency Decay Rate 4
81-H5
5th Harmonic Level
81O
Overfrequency
87
Differential (Percent)
50/87
Instantaneous Differential
AN-1
Analog Input Level 1
AN-2
Analog Input Level 2
Insulation Aging: Aging Factor, Hottest
Spot Limit, and Total Accumulated Life
Tap Changer Monitor
Symbol
Winding 2 Protection Element
250/46
Negative Sequence Instantaneous
Overcurrent
251/46
Negative Sequence Time Overcurrent
250P1
Phase Instantaneous Overcurrent 1
250P2
Phase Instantaneous Overcurrent 2
250N1
Neutral (3I
) Instantaneous Overcurrent 1
0
250N2
Neutral (3I
) Instantaneous Overcurrent 2
0
250G1
Ground Instantaneous Overcurrent 1
250G2
Ground Instantaneous Overcurrent 2
251P
Phase Time Overcurrent
251N
Neutral (3I
) Time Overcurrent
0
251G
Ground Time Overcurrent
287TG
Ground Differential (Restricted Ground
Fault)
2THD
Total Harmonic Distortion Level
2AD
Current Demand
2–2
745
The following table outlines the protection features available for Windings 1, 2, and
3, as well as the common protection elements.
http://www.GEindustrial.com/multilin
Symbol
Winding 1 Protection Elements
150/46
Negative Sequence Instantaneous
Overcurrent
151/46
Negative Sequence Time Overcurrent
150P1
Phase Instantaneous Overcurrent 1
150P2
Phase Instantaneous Overcurrent 2
150N1
Neutral (3I
) Instantaneous Overcurrent 1
0
150N2
Neutral (3I
) Instantaneous Overcurrent 2
0
150G1
Ground Instantaneous Overcurrent 1
150G2
Ground Instantaneous Overcurrent 2
151P
Phase Time Overcurrent
151N
Neutral (3I
) Time Overcurrent
0
151G
Ground Time Overcurrent
187TG
Ground Differential (Restricted Ground
Fault)
1THD
Total Harmonic Distortion Level
1AD
Current Demand
Symbol
Winding 3 Protection Elements
350/46
Negative Sequence Instantaneous
Overcurrent
351/46
Negative Sequence Time Overcurrent
350P1
Phase Instantaneous Overcurrent 1
350P2
Phase Instantaneous Overcurrent 2
350N1
Neutral (3I
) Instantaneous Overcurrent 1
0
350N2
Neutral (3I
) Instantaneous Overcurrent 2
0
351P
Phase Time Overcurrent
351N
Neutral (3I
) Time Overcurrent
0
351G
Ground Time Overcurrent
387TG
Ground Differential (Restricted Ground
Fault)
3THD
Total Harmonic Distortion Level
3AD
Current Demand