GE Multilin 745 Instruction Manual page 194

Transformer management relay
Table of Contents

Advertisement

745
Transformer Management Relay
6–22
This flash message is displayed while changing the passcode
PLEASE ENTER A
from the
NON-ZERO PASSCODE
setpoint. An attempt was made to change the passcode to
when it was already
This flash message is displayed for 5 seconds in response to
PRESS [ENTER] TO
pressing the decimal key followed by ENTER while displaying
ADD AS DEFAULT
any setpoint or actual value message except the
SETUP !" DEFAULT MESSAGES !" SELECTED DEFAULTS
setpoint. Pressing ENTER again while this message is
displayed adds the setpoint or actual value message to the
default list.
This flash message is displayed in response to pressing the
PRESS [ENTER] TO
VALUE keys while on a setpoint message with a text entry
BEGIN TEXT EDIT
value. The ENTER key must first be pressed to begin editing.
This flash message is displayed for 5 seconds in response to
PRESS [ENTER] TO
pressing the decimal key followed by ENTER while displaying
REMOVE MESSAGE
one of the selected default messages in the
DEFAULT MESSAGES !" SELECTED DEFAULTS
ENTER again while this message is displayed removes the
default message.
This flash message is displayed in response to any pressed
PRESSED KEY
key that has no meaning in the current context.
IS INVALID HERE
This flash message is displayed in response to pressing RESET
RESETTING LATCHED
when the relay is in local mode. All active targets for which
CONDITIONS
the activating condition is no longer present will be cleared.
This flash message is displayed in response to pressing ENTER
SETPOINT ACCESS
while on any setpoint message. Setpoint access is restricted
DENIED (PASSCODE)
because the programmed passcode has not been entered to
allow access.
This flash message is displayed in response to pressing ENTER
SETPOINT ACCESS
while on any setpoint message. Setpoint access is restricted
DENIED (SWITCH)
because the setpoint access terminals have not been
connected.
This flash message is displayed in response to entering the
SETPOINT ACCESS
programmed passcode at the
IS NOW ALLOWED
ALLOW SETPOINT WRITE ACCESS
allow write access to setpoints has been successfully
executed and setpoints can be changed and entered.
This flash message is displayed in response to correctly
SETPOINT ACCESS
entering the programmed passcode at
IS NOW RESTRICTED
PASSCODE !" ALLOW SETPOINT WRITE ACCESS
to restrict access to setpoints has been successfully
executed and setpoints cannot be changed.
http://www.GEindustrial.com/multilin
Target and Flash Messages
S1 745 SETUP ! PASSCODE !" CHANGE PASSCODE
0
.
S1 745 SETUP !" PASSCODE !"
setpoint. The command to
0
S1 745
S1 745 SETUP !"
menu. Pressing
S1 745 SETUP !"
. The command
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents