JOINT 1 PIN
TX+
1
TX-
2
RX+

RX-

CONNECTOR PIN
TX+
TX-
RX+
RX-
poweR supply poRT
Insert the Power Adapter point to this port for power.
Rs232/Rs485/wiegAnd ConneCTion poRT
RS22 –
Connection to a computer using RS232 cable.
RS85 Single Connection -
RS85 Network Connection -
Wiegand Output –
Connecting with third party connector or terminal(s).
ACCess ConTRol poRT
Linking the terminal to door lock system.
Bell poRT
Linking the terminal to doorbell.
Ingress Online Activation
Ingress is a genuine software by FingerTec. Every FingerTec access control model comes
bundled with a unique license key. To start using the terminal with Ingress, you must
connect the terminal to Ingress and perform online activation. Ingress reads the serial
number of your terminal and sends it for verification at the FingerTec server via Internet.
In case you do not have an Internet connection, you would need to do offline activation.
Please send the serial number and models of your terminals to your local resellers or sup-
port@fingertec.com to request for a product key and activation key.
Installation and Setup of Ingress
Install Ingress in a PC that fulifills Ingress' minimum requirements. Refer to http://www.
fingertec.com/customer/download/postsales/SUM-Ingress-E.pdf for the Ingress user
guide online. Setup Wizard will require you to do online activation before connection
establish between Ingress and terminals.
JOINT 2 PIN
 RX+
 RX-
1 TX+
2 TX-
CABLE COLOR
1
2


5


8
Connection to a single computer using RS485 wire.
Connection to multiple computers using Daisy Chain connection.
noTe
TCP/IP for Network Connection –
the terminals to multiple computers using TCP/
IP requires Ethernet 10/100Base-T Straight Thru
Cable or "whips". The cable works with both
10Base-T and 100Base-TX, connecting a network
interface card to a hub or network outlet.
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Link all cables to the correct connection point(s)
before attempting to connect the terminals to
software.
Linking
CONNECTOR
1
TX+
2
TX-

RX+

5

RX-

8
CONTENTS
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents