Download Print this page
FingerTec R2c User Manual

FingerTec R2c User Manual

Slave fingerprint access control terminal

Advertisement

Quick Links

w w w . f i n g e r t e c . c o m
w w w . f i n g e r t e c . c o m
R2c
Slave Fingerprint Access
Control Terminal
User Guide
©
2000-2014 FingerTec Worldwide Limited. All rights reserved • 032014
R2c
suppor t@finger tec.com
1
Introduction
LED Light Indicator
The red light indicates either
standby or failed verification.
The green light indicates that the
fingerprint or card information is
being read and sent to the
master terminal for verification.
Fingerprint Scanner
Scans and sends fingerprint
templates to the master terminal
for verification.
Card Scanning Area
Reads and captures details of cards
and sends it to the master terminal
for verification. The default card
technology is RFID. Mifare and HID
technology
are
available
upon
request.
Connections & Wiring Diagram
2
Dip Switch Setting
Back piece
Emits audio indication for verification results.
One beep – Successful verification.
Two beeps – Unsuccessfull verification.
R2c
suppor t@finger tec.com
Dip Switch
To set the device ID of the terminal. Use this only if you
are installing the terminal with an Ingressus controller.
Rear of Master
Rear of R2c Terminal
Terminal
*Yellow – RS 485+
Blue – RS 485+
*Purple – RS 485 -
Yellow – RS 485 -
Black - GND
Black - GND
Red – +12V
+
12VDC power
_
Black – GND
supply
Note:
1. The R2c will only work with R2 (FEM 565), AC900, Q2i, i-Kiosk 100 Plus and
H2i master terminals.
2. The R2c can share the 12VDC power supply with the master terminal.
3. It is recommended to use RS485 connection cables with a shielded twisted
pair to achieve an optimum speed of data transfer.
4. Do not adjust the dip switch unless you are connecting the R2c with the
Ingressus controller. If your R2c is unable to send any fingerprint or card
data to the master terminal, please check the dip switch. Make sure it is set
to the default settings as highlighted.
Speaker

Advertisement

loading

Summary of Contents for FingerTec R2c

  • Page 1 Dip Switch Setting Back piece Note: 1. The R2c will only work with R2 (FEM 565), AC900, Q2i, i-Kiosk 100 Plus and H2i master terminals. 2. The R2c can share the 12VDC power supply with the master terminal. 3. It is recommended to use RS485 connection cables with a shielded twisted pair to achieve an optimum speed of data transfer.
  • Page 2 Please read the instructions carefully before installing the R2c. Make sure the R2c is in standby mode, where the green LED light is blinking and a card ID has been enrolled into a master terminal before you proceed to verify.