JASON Hydrotherapy forma Owner's Manual

Hide thumbs Also See for forma:

Advertisement

Quick Links

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
MADE IN THE U.S.A.
forma
INSTALLATION, OPERATION, AND MAINTENANCE
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of Lading.
INSPECTION
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the Bill of
Lading.
NOTE: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier
to respond should be reported to the seller and carrier.
Always file a freight claim promptly.
The installer is responsible for insuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
OWNER'S RECORD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
OWNER'S MANUAL
and Designer MicroSilk
®
Page 1 of 16
Baths
®
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage, keep the bath in the
carton until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access to
all hydrotherapy bath equipment, controls and electrical
connections must be provided during installation
(Recommended minimum 28" x 17" [71 x 43 cm]).
Insufficient access will hinder repair and maintenance.
Warranty service will not cover costs of providing
equipment access.
Jason offers an optional removable lateral skirt for all
rectangular baths. The skirts are available in matching
acrylic colors and provide convenient access to bath
equipment, as well as an excellent finished appearance.
The Specification Sheet for this bath contains additional
technical information. This sheet can be provided by your
dealer or accessed online at www.jasoninternational.com.
PLACE SERIAL NUMBER CARD WITH
PRODUCT CONFIGURATION IN THIS BOX
49-1010-604
Date 05/2018
Customer Service : 800.255.5766
Copyright © 2014 Jason International

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the forma and is the answer not in the manual?

Questions and answers

Summary of Contents for JASON Hydrotherapy forma

  • Page 1 49-1010-604 8328 MacArthur Drive Date 05/2018 North Little Rock, AR 72118 www.jasoninternational.com MADE IN THE U.S.A. OWNER’S MANUAL forma and Designer MicroSilk Baths ® ® INSTALLATION, OPERATION, AND MAINTENANCE If the carton shows sign of damage, inspect Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer.
  • Page 2: Installation

    INSTALLATION INSTRUCTIONS INSTALLATION assembly. At this time, considerations should be made for the position and mounting of the faucet set, as well as all See the USER MAINTENANCE INSTRUCTIONS section related plumbing. of this owner’s manual, prior to Installation, for humidity and mold prevention suggestions.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) Figure 3 FIELD INSTALLATION To install the MicroSilk ® Pump Assembly to the bath, the follow- ing procedures must be followed. ® OF THE MICROSILK PUMP ASSEMBLY Note: Do not install the MicroSilk ® Pump Assembly further than The Jason MicroSilk ®...
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) ® ® ® ® 4. Clamp the MicroSilk Jet Line to the MicroSilk 6. Clamp the MicroSilk Drain Line to the MicroSilk Drain Discharge Barb using the clamp provided on the tubing. Barb using the clamp provided on the tubing. Assure the ®...
  • Page 5: Manufacturer's Warranty

    INSTALLATION INSTRUCTIONS (cont.) ELECTRICAL ® 4. 120V Electrical Service- MicroSilk Control Box. ® The MicroSilk generator unit may be shipped separate from Electrical Power Supply: These instructions are written as- ® the bath. Follow the instructions for the MicroSilk Pump suming 60Hz, 120v power supply.
  • Page 6 INSTALLATION INSTRUCTIONS (cont.) Figure 8 Standard / Premier Signature Edition Edition GROUND Key Pad DEDICATED 240V,50 or 60 Hz Ground - Green Wire GFCI PROTECTED Neutral - White Wire SERVICE Key Pad Cable Hot - Black Wire Dedicated 120V, 50 or 60 Hz GFCI Protected Service NOTE: USE THE ABOVE...
  • Page 7: Water Testing

    INSTALLATION INSTRUCTIONS (cont.) CLEANING WATER TESTING Remove all loose debris. Construction plaster or excess Before finishing the installation, it is recommended that the bath be grout can be removed with the use of a wood (edge) trowel. water tested and the plumbing tested for leaks. 2.
  • Page 8 INSTALLATION INSTRUCTIONS (cont.) MICROSILK CONTROL BOX CONNECTIONS ® STANDARD EDITION MICROSILK ® The MicroSilk Control Box ® Jason’s Standard Edition MicroSilk system features the ® The MicroSilk unit and keypad must be plugged into the ® best in luxury bathing for the leisure bath industry. To proper receptacles for correct operation of the MicroSilk ®...
  • Page 9 INSTALLATION INSTRUCTIONS (cont.) PREMIER EDITION MICROSILK ® The MicroSilk Control Box ® Jason’s Premier Edition MicroSilk system incorporates all ® The MicroSilk unit, keypad, LED light, and Ozone Sanita- ® the features of the Standard Edition system and includes tion Unit must be plugged into the proper receptacles for the benefits of an ozone sanitation system and an LED correct operation of the MicroSilk system.
  • Page 10 CONTROL BOX CONNECTIONS (cont.) ® SIGNATURE EDITION MICROSILK The MicroSilk Control Box ® The MicroSilk ® unit, keypad, LED light, Ozone Sanitation Unit Jason’s Signature Edition MicroSilk ® system is the most and Water Level/Temperature Sensor must be plugged into advanced bath manufactured by Jason International, Inc.
  • Page 11 OPERATING INSTRUCTION, FEATURES, AND CONTROLS Signature Touchpad INTRODUCTION A main control touchpad mounted on the bath deck This manual contains all of the information needed for the features an LCD readout which alternately indicates the ® proper installation and operation of your Jason MicroSilk water temperature (+/- 5 F) and time remaining.
  • Page 12 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) STANDARD AND PREMIER EDITION MICROSILK TOUCHPAD ® Figure 12 ® ® MICROSILK LED Light MicroSilk On/Off ® LED Light Icon OPERATING INSTRUCTIONS The LED Light icon is used to operate an LED light (if MicroSilk ®...
  • Page 13 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) SIGNATURE EDITION MICROSILK TOUCHPAD ® For Diagnostic Functions Figure 13 For Diagnostic Functions LED Light MicroSilk On/Off ® IR for Remote OPERATING INSTRUCTIONS Menu Instructions Use the top Diagnostic Function icon to scroll through the ®...
  • Page 14: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY CLEANING With minimum care, your acrylic-surfaced bath will retain its WARNING: Avoid high humidity levels in your home. high-luster finish for many years. For regular cleaning use Mold, mildew, fungi and bacteria which may be harmful Jason Bath Cleaner or a mild NONABRASIVE liquid detergent to health thrive in areas with continued high humidity solution (i.e.
  • Page 15: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY REPAIRS MUST BE AUTHORIZED BY JASON BEFORE WORK IS STARTED. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER WARNING: Always turn off power at the mail electrical service panel when servicing the bath.
  • Page 16 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. This manual contains information and instructions for proper operation and maintenance of your hydrotherapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. WARNING: When using this unit, basic precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY...

This manual is also suitable for:

Designer microsilkMicrosilk

Table of Contents