Download Print this page

Advertisement

Quick Links

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
INsTallaTION, OPeraTION, aND MaINTeNaNCe
INSPECTION
Inspection of the unit prior to installation is the responsibility
of the installer. All components are assembled to the
bath and the unit is water tested and inspected prior to
leaving Jason International, Inc. If the carton shows sign of
damage, inspect the product before accepting and describe
the problem on the Bill of Lading. Note: Transportation
and insurance from Jason's factory are the buyer's
responsibility.
Damage sustained in transit is the responsibility of the carrier.
If damage is discovered, the carrier must be immediately
notified in writing with a request for a representative to
inspect the unit. Failure of the carrier to respond should be
reported to the seller and carrier. Always file a freight claim
promptly.
The installer is responsible for insuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit. Jason International is not
responsible for damage that might have been avoided by
inspection or testing prior to installation.
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer. ALL
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE
OwNer's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
OwNer's MaNual
AC635P forma™ AirMasseur
CAUTION: DO NOT LIFT OR HANDLE THE BATH BY ITS PLUMBING.
MUST BE MADE PRIOR TO INSTALLATION. Inspect
plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the unit in its carton
until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access
to all therapy bath equipment, controls, and electrical
connections must be provided during installation. (See Table
1 - Specifications for minimum access size). .) Insufficient
access will hinder repair and maintenance. Warranty service
will not cover the cost of providing equipment access.
TABLE 1 - SPECIFICATIONS
Overall
Dimension
Model
L x W x H (in.)
AC635P
42 x 72 x 22
PlaCe serIal NuMBer CarD wITH
PrODuCT CONFIGuraTION IN THIs BOx
Page 1 of 15
Bath
®
Operating
Blower
Min. Size
Capacity
120v /
Access
Gal
240v HP
W x H (in.)
56
1
36 x 17
Customer Service : 800.255.5766
49-1000-113
Date
11/07
Floor
Loading
lbs/ft
2
53.8 lbs

Advertisement

loading

Summary of Contents for JASON Hydrotherapy Forma AirMasseur AC635P

  • Page 1 “TO BE REMOVED FOR USE BY THE OCCUPANT.” Jason International, Inc. 49-1000-113 8328 MacArthur Drive Date 11/07 North Little Rock, AR 72118 www.jasoninternational.com OwNer’s MaNual AC635P forma™ AirMasseur Bath ® INsTallaTION, OPeraTION, aND MaINTeNaNCe INSPECTION MUST BE MADE PRIOR TO INSTALLATION. Inspect plumbing and bath surface for missing or damaged Inspection of the unit prior to installation is the responsibility components.
  • Page 2 INSTALLATION INSTRUCTIONS Remove the product from its packaging. Read the entire 6. Mark on the sub-floor the sump area location; the water inlet stub-out location; and the remote blower-tubing floor instructions prior to installing this product. cut out location. Two remote blower tubing floor cutout 1.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) any authorized Jason International, Inc. dealer. Position 8. After the finished floor is installed, position the installation template on the finished floor. Place the template to line up the bath in place and attach the drain and overflow to the floor drain “P”...
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) REMOTE MOUNTING Of AIR bLOwER 15.Using the remaining five (5) holes in the skirt as a template, drill five (5) pilot holes into the floor and use the remaining Do not remote mount the blower and control box more 5/16”...
  • Page 5 INSTALLATION INSTRUCTIONS (cont.) 5. Extend piping stubout through the floor as illustrated in 8. Before finishing the installation, it is recommended that the Figure 7. Piping between the remote blower location and bath controls be tested without filling the bath with water the bath can be insulated using a minimum of 1/2”...
  • Page 6 INSTALLATION INSTRUCTIONS (cont.) NOTe: Follow the manufacturers instructions for safely 12.Complete the installation of the drain and overflow per the using these or similar products. If the surface becomes instructions included with the drain and overflow. scratched or dulled, it may be restored by using a quality 13.It is recommended that the bath be water tested (filled and plastic polish, i.e., Novus Plastic Polish No.
  • Page 7 INSTALLATION INSTRUCTIONS (cont.) DaNGer — rIsK OF eleCTrIC sHOCK: Connect only to a ELECTRICAL circuit protected by a Ground Fault Circuit Interrupter (GFCI). NOTe: The bath is designed for indoor use only. The In the unlikely occurrence of a current imbalance in the electrical equipment must not be exposed to direct or power conductors, the GFCI will interrupt the power to the indirect water or moisture contact.
  • Page 8 fEATURES Of ThE DESIGNER AIRMASSEUR bATh ® STANDARD EDITION AIRMASSEUR ® TOUChPAD fEATURES bLOwER fEATURES One main control touchpad mounted on the bath deck The Jason Standard Edition AirMasseur system provides ® contains several icons used by the bather to control the a variable speed, controlled heated air blower with three (3) blower and optional light.
  • Page 9: Control Box Connections

    AIRMASSEUR CONTROL bOx CONNECTIONS ® STANDARD EDITION AIRMASSEUR ® Jason’s Standard Edition AirMasseur system features the ® best in luxury bathing for the leisure bath industry. To assure STANDARD EDITION AIRMASSEUR PARTS LIST that your bath functions properly the blower control must be ®...
  • Page 10 GENERAL OPERATING INSTRUCTIONS INTRODUCTION SIGNATURE EDITION AUTOMATIC PURGE This manual contains all of the information needed for the Twenty (20) minutes after the control has shut off and the bath proper installation and operation of your Jason AirMasseur is completely drained, the blower will start again for a 2-minute ®...
  • Page 11 OPERATING ThE STANDARD EDITION AIRMASSEUR ® Mode Blower Speeds Figure 13 Option AirMasseur fEATURES The Jason Standard Edition AirMasseur touchpad is used ® to access all the functions of the blower control. OPERATING INSTRUCTIONS: AirMasseur Icon blower Speeds Icon ® The AirMasseur icon is used to activate the blower and the The Blower Speeds icon is used to increase or decrease...
  • Page 12 OPERATING ThE SIGNATURE EDITION AIRMASSEUR ® TOUChPAD Blower On/Off, Modes Figure 14 Blower Speeds LED Light IR for Remote fEATURES OPTION ICON The Jason Signature Edition Digital AirMasseur touchpad ® This key is reserved for future options. is used to access all of the functions of the control box used in a Jason Signature Edition AirMasseur bath.
  • Page 13: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS hUMIDITY SURfACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored Warning: Avoid high humidity levels in your home. Mold, mildew, by applying commercially available plastic polish (i.e. Novus fungi, and bacteria which may be harmful to health thrive in areas with Plastic Polish No.
  • Page 14: Troubleshooting Guide

    TROUbLEShOOTING GUIDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY REPAIRS MUST BE AUTHORIzED BY JASON BEFORE WORk IS STARTED. FOR SERVICE, CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER.
  • Page 15: Important Safety Instructions

    IMPOrTaNT saFeTY INsTruCTIONs INsTruCTIONs PerTaINING TO a rIsK OF FIre, eleCTrIC sHOCK, Or INJurY TO PersONs warNING: When using this unit, basic precautions should always be followed, including the following: This manual contains information and instructions for proper operation and maintenance of your therapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire.