"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
InsTallaTIOn, OPeraTIOn, anD MaInTenanCe
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of lading.
InsPeCTIOn
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the Bill of
Lading.
NOTe: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of the
carrier. If damage is discovered,
Owner's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
Owner's Manual
forma
Microsilk
®
Page 1 of 18
Baths
TM
the carrier must be immediately notified in writing with a
request for a representative to inspect the unit. Failure of
the carrier to respond should be reported to the seller and
carrier. Always file a freight claim promptly.
The installer is responsible for insuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer. ALL
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE
MUST BE MADE PRIOR TO INSTALLATION. Inspect
plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the
carton until ready for installation.
PlaCe serIal nuMBer CarD wITh
PrODuCT COnfIguraTIOn In ThIs BOx
49-1011-600
Date 03/11
Customer Service : 800.255.5766
Copyright © 2011 Jason International.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the forma MicroSilk AC553 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JASON Hydrotherapy forma MicroSilk AC553

  • Page 1 “TO BE REMOVED FOR USE BY THE OCCUPANT.” Jason International, Inc. 49-1011-600 8328 MacArthur Drive Date 03/11 North Little Rock, AR 72118 www.jasoninternational.com Owner’s Manual forma Microsilk Baths ® InsTallaTIOn, OPeraTIOn, anD MaInTenanCe If the carton shows sign of damage, inspect the carrier must be immediately notified in writing with a request for a representative to inspect the unit.
  • Page 2: Installation Instructions

    instALLAtiOn instRuctiOns EquipmEnt AccEss Jason offers an optional removable lateral skirt for all rect- angular baths. The skirts are available in matching acrylic In accordance with Building Codes, service access to all colors and provide convenient access to bath equipment therapy bath equipment, controls and electrical connections as well as an excellent finished appearance.
  • Page 3: Installation

    instALLAtiOn instRuctiOns (cont.) instALLAtiOn Jason offers a removable lateral skirt for most baths. each bath is provided with a cardboard bath well protec- The skirts are available in matching acrylic colors tor that should be kept in the unit during the installation and provide convenient access to bath equipment as and throughout the bathroom construction process.
  • Page 4 instALLAtiOn instRuctiOns (cont.) Figure 4 the bath is installed in a drop-in application. In alcove installations, a bed of mortar may also be recommended to aid in leveling the bath. Note: Do not use a sand bed to install or level the bath. Secure the bottom of all equipment mounts so that it is level with the bottom of the bath.
  • Page 5 instALLAtiOn instRuctiOns (cont.) This could cause system blockage and equipment Figure 9 damage. Remove the protective caps from the MicroSilk™ Jet Flex Hose and the MicroSilk™ Suction Line that are located on the bath (See Figure 5), also remove the protective caps Figure 7 Suction Barb using the clamp provided on the tubing.
  • Page 6 instALLAtiOn instRuctiOns (cont.) ELEctRicAL is to be done by a Massachusetts licensed plumber. eLeCTRICAL POWeR SUPPLY: These instructions are written Standard/Premier edition MicroSilk™ Control box (120v). assuming 60Hz, 120v (or 240v for Signature Edition) power supply. The MicroSilk generator unit is shipped separate from the bath. Special notations are also included for the Export versions of the Follow the instructions for the MicroSilk Pump Assembly pump, control equipment and power supply.
  • Page 7 instALLAtiOn instRuctiOns (cont.) Figure 9 standard/ premier Edition microsilk GROUND Key Pad DEDICATED 240V,50 or 60 Hz Ground - Green Wire GFCI PROTECTED Neutral - White Wire SERVICE Key Pad Cable Hot - Black Wire Dedicated 120V, 50 or 60 Hz GFCI Protected Service Light...
  • Page 8: Water Testing

    instALLAtiOn instRuctiOns (cont.) WAtER tEsting cLEAning Remove all loose debris. Construction plaster or Before finishing the installation, it is recommended that the excess grout can be removed with the use of a wood bath be water tested and the plumbing tested for leaks. (edge) trowel.
  • Page 9 micROsiLK cOntROL bOx cOnnEctiOns stAnDARD EDitiOn micROsiLK stAnDARD EDitiOn micROsiLK pARts List Jason’s Standard Edition MicroSilk system features the best in luxury bathing for the leisure bath industry. To assure that MicroSilk Pump Unit Pump Control Box your bath functions properly, the MicroSilk pump control box Control Box Stand Water Level/Vacuum Sensor must be properly connected.
  • Page 10 cOntROL bOx cOnnEctiOns (cont.) signAtuRE EDitiOn micROsiLK Jason’s Signature Edition MicroSilk system is the most ad- signAtuRE EDitiOn micROsiLK pARts List vanced bath manufactured by Jason International, Inc. and features the ultimate in luxury bathing for the leisure bath MicroSilk Pump Unit Pump Control Box industry.
  • Page 11 OpERAting instRuctiOn, FEAtuREs, AnD cOntROLs intRODuctiOn signature touchpad This manual contains all of the information needed for the proper installation and operation of your Jason MicroSilk bath. A main control touchpad mounted on the bath deck features a LCD The MicroSilk bath has been designed to give you years of readout which alternately indicates the water temperature (+/- 5 relaxing trouble-free service, provided the unit is maintained F) and time remaining.
  • Page 12 OpERAting instRuctiOns, FEAtuREs, AnD cOntROLs (cont.) FiLLing AnD DRAining Close the drain and fill the bath with water at least two (2) inches (50mm) above the jets. The inlet temperature should not exceed 40 C (104 F) as this could damage the acrylic surface.
  • Page 13 stAnDARD AnD pREmiER EDitiOn micROsiLK tOuchpAD MICROSILK LED Light MicroSilk™ On/Off Figure 13 LED Light (Light icon) The Jason Standard and Premier Edition MicroSilk touchpad is used to access all of the functions of the pump control. The LED Light icon is used to operate an LED light (if installed). OpERAting instRuctiOns •...
  • Page 14: Remote Control

    signAtuRE EDitiOn micROsiLK tOuchpAD For Diagnostic Functions For Diagnostic Functions LED Light MicroSilk™ On/Off IR for Remote Display Panel Figure 14 The Jason Signature Edition MicroSilk digital touchpad is the top icon to change from Product Test to the Temperature used to access all the functions of the Jason Signature option.
  • Page 15: User Maintenance Instructions

    usER mAintEnAncE instRuctiOns humiDity If scratches are too deep to rub out, or if the damage penetrates the acrylic surface, consult your dealer for recommendations warnIng: avOID hIgh huMIDITy levels In yOur hOMe. MOlD, on surface repair. MIlDew, fungI anD BaCTerIa whICh May Be harMful TO healTh ThrIve In areas wITh COnTInueD hIgh huMIDITy FLushing / sAnitiZing levels;...
  • Page 16: Troubleshooting Guide

    tROubLE shOOting guiDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. All warranty repairs must be authorized by Jason before work is started. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER WARNING: Always turn off power at the main electrical service panel when servicing the bath.
  • Page 17: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS InsTruCTIOns PerTaInIng TO The rIsk Of fIre, eleCTrIC shOCk, Or InJury TO PersOns. This manual contains information and instructions for proper operation and maintenance of your therapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. warnIng: when using this unit, basic precautions should always be followed, including the following: reaD anD fOllOw all InsTruCTIOns Carefully...