INSTALLATION, OPERATION, AND MAINTENANCE
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of Lading.
INSPECTION
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the
Bill of Lading.
NOTE: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier
to respond should be reported to the seller and carrier.
Always file a freight claim promptly.
The installer is responsible for ensuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
OWNER'S RECORD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
OWNER'S MANUAL
®
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage, keep the bath in the
carton until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access to
all hydrotherapy bath equipment, controls and electrical
connections must be provided during installation
(Recommended minimum 28" x 17" [71 x 43 cm]).
Insufficient access will hinder repair and maintenance.
Warranty service will not cover costs of providing
equipment access.
Jason offers an optional removable lateral skirt for all
rectangular baths. The skirts are available in matching
acrylic colors and provide convenient access to bath
equipment, as well as an excellent finished appearance.
The Specification Sheet for this bath contains additional
technical information. This sheet can be provided by your
dealer or accessed online at www.jasoninternational.com.
Page 1 of 18
-AirMasseur
®
PLACE SERIAL NUMBER CARD WITH
PRODUCT CONFIGURATION IN THIS BOX
Customer Service : 800.255.5766
Copyright © 2014 Jason International.
49-1010-801
Date 05/2018
Baths

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the forma Designer MicroSilk AirMasseur and is the answer not in the manual?

Questions and answers

Summary of Contents for JASON Hydrotherapy forma Designer MicroSilk AirMasseur

  • Page 1 “TO BE REMOVED FOR USE BY THE OCCUPANT.” Jason International, Inc. 49-1010-801 8328 MacArthur Drive Date 05/2018 North Little Rock, AR 72118-2029 www.jasoninternational.com MADE IN THE USA OWNER’S MANUAL forma and Designer MicroSilk -AirMasseur Baths ® ® ® INSTALLATION, OPERATION, AND MAINTENANCE If the carton shows sign of damage, inspect Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION shell according to the instructions provided with the See the USER MAINTENANCE INSTRUCTIONS section drain and position the bath in the area of intended installation. of this owner’s manual, prior to installation, for humidity and mold prevention suggestions. 5.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) Figure 3 Fu ll Su p p o r t B a s e 10. Protect the acrylic bath surface from damage WARNING: SYSTEM UNDER PRESSURE – NEVER during installation with a suitable material, i.e., PERFORM MAINTENANCE WHILE SYSTEM IS RUNNING. cardboard and/or plastic film.
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) ® ® Caution: Confirm all tubing is fully engaged on 4. Clamp the MicroSilk Jet Line to the MicroSilk its respective barb and its clamp has secured the Discharge Barb using the clamp provided on the ® tubing to the barb.
  • Page 5 INSTALLATION INSTRUCTIONS (cont.) ELECTRICAL ® 4. 120V Electrical Service MicroSilk -AirMasseur ® Electrical Power Supply: These instructions are written ® Control Box. The MicroSilk generator unit may be assuming 60Hz, 120V power supply. Special notations are shipped separate from the bath. Follow the instructions for also included for export versions of the equipment and ®...
  • Page 6 INSTALLATION INSTRUCTIONS (cont.) Figure 8 MICROsilk™-Air Standard / Premier Signature Edition Edition GROUND Gr o u n d - Gr een Wir e Sa n i- Des ig n Neu t r a l - Wh it e Wir e C lea n in g Sys t em Ho t - B la c k Wir e...
  • Page 7: Water Testing

    INSTALLATION INSTRUCTIONS (cont.) WATER TESTING CLEANING Before finishing the installation, it is recommended that the bath 1. Remove all loose debris. Construction plaster or excess be water tested and the plumbing tested for leaks. grout can be removed with the use of a wood (edge) trowel.
  • Page 8 INSTALLATION INSTRUCTIONS (cont.) MICROSILK -AIRMASSEUR ® CONTROL BOX CONNECTIONS ® STANDARD EDITION MICROSILK -AIRMASSEUR ® ® The MicroSilk -AirMasseur Control Box ® ® The MicroSilk unit, blower, and keypad must be plugged into ® ® ® Jason’s Standard Edition MicroSilk -AirMasseur system ®...
  • Page 9 INSTALLATION INSTRUCTIONS (cont.) PREMIER EDITION MICROSILK -AIRMASSEUR ® ® The MicroSilk -AirMasseur Control Box ® ® Jason’s Premier Edition MicroSilk -AirMasseur system ® ® The MicroSilk unit, blower, keypad, LED light, and Ozone ® incorporates all the features of the Standard Edition Sanitation Unit must be plugged into the proper receptacles system and includes the benefits of an ozone sanitation for correct operation of the MicroSilk...
  • Page 10 CONTROL BOX CONNECTIONS (cont.) SIGNATURE EDITION MICROSILK -AIRMASSEUR The MicroSilk -AirMasseur Control Box ® ® ® ® ® ® Jason’s Signature Edition MicroSilk -AirMasseur system is The MicroSilk ® unit, blower, keypad, LED light, Ozone the most advanced bath manufactured by Jason International, Sanitation Unit and Water Level/Temperature Sensor must Inc.
  • Page 11: Features And Controls

    OPERATING INSTRUCTION, FEATURES, AND CONTROLS INTRODUCTION SIGNATURE EDITION MICROSILK -AIRMASSEUR ® ® The Jason Signature Edition MicroSilk -AirMasseur bath ® ® This manual contains all of the information needed for the includes both a Microbubble generator unit and an air bath proper installation and operation of your Jason MicroSilk ®...
  • Page 12 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) Port NOTE: If the unit fails to operate, check the breaker panel to ensure that the circuit breaker is on. Check the GFCI by testing A strategically placed MicroSilk port is provided for complete ®...
  • Page 13 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) ® ® STANDARD AND PREMIER EDITION MICROSILK -AIRMASSEUR TOUCHPAD Figure 12 NOTE:To ensure the full effects of the MicroSilk system, Blower Speeds Icon ® the AirMasseur and MicroSilk systems can not be ® ® The Blower Speeds icon is used to increase or decrease operated at the same time.
  • Page 14 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) ® SIGNATURE EDITION MICROSILK -AIRMASSEUR TOUCHPAD Figure 13 is connected to a power supply. This function has a two-hour NOTE:To ensure the full effects of the MicroSilk system, ® timer and remembers the last mode. The LCD displays “Light the AirMasseur and MicroSilk systems can NOT be...
  • Page 15: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be WARNING: Avoid high humidity levels in your home. restored by applying commercially available plastic Mold, mildew, fungi and bacteria which may be harmful polish (i.e. Novus Plastic Polish No. 2, available at your to health thrive in areas with continued high humidity Jason dealer), followed by an application of acrylic paste levels;...
  • Page 16: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY REPAIRS MUST BE AUTHORIZED BY JASON BEFORE WORK IS STARTED. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER WARNING: Always turn off power at the mail electrical service panel when servicing the bath.
  • Page 17: Warranty

    Troubleshooting Guide (cont.) AIRMASSEUR BLOWER SYSTEM ® SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTION a) No power to air bath unit. a) Reset circuit breakers and check GFCI. Check fuses and replace if bad. b) Blower motor is not plugged in. b) Make sure plug is fully inserted into the outlet. Air bath system won’t operate.
  • Page 18 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. This manual contains information and instructions for proper operation and maintenance of your hydrotherapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. WARNING: When using this unit, basic precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY DANGER:...