JASON Hydrotherapy Integrity Owner's Manual

Hide thumbs Also See for Integrity:

Advertisement

Quick Links

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118-2029
www.jasoninternational.com
Integrity
Soaking, MicroSilk
®
INSTALLATION, OPERATION, AND MAINTENANCE
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of Lading.
INSPECTION
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the Bill of
Lading.
NOTE: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier
to respond should be reported to the seller and carrier.
Always file a freight claim promptly.
The installer is responsible for ensuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
OWNER'S RECORD
Dealer:
Date Purchased:
Date Installed:
Installer:
501.771.4477
OWNER'S MANUAL
, AirMasseur
®
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the
carton until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access to
all hydrotherapy bath equipment, controls and electrical
connections must be provided during installation
(Recommended minimum 28" x 17" [71 x 43 cm]).
Insufficient access will hinder repair and maintenance.
Warranty service will not cover costs of providing
equipment access.
Jason offers an optional removable lateral skirt for all
rectangular baths. The skirts are available in matching
acrylic colors and provide convenient access to bath
equipment, as well as an excellent finished appearance.
The Specification Sheet for this bath contains additional
technical information. This sheet can be provided by your
dealer or accessed online at www.jasoninternational.com.
Page 1 of 12
, Whirlpool Baths
®
PLACE SERIAL NUMBER CARD WITH
PRODUCT CONFIGURATION IN THIS BOX
Customer Service : 800.255.5766
Copyright © 2013 Jason International.
49-1013-001
Date
02/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integrity and is the answer not in the manual?

Questions and answers

Summary of Contents for JASON Hydrotherapy Integrity

  • Page 1 Jason International, Inc. 49-1013-001 8328 MacArthur Drive Date 02/13 North Little Rock, AR 72118-2029 www.jasoninternational.com OWNER’S MANUAL Integrity Soaking, MicroSilk , AirMasseur , Whirlpool Baths ® ® ® INSTALLATION, OPERATION, AND MAINTENANCE If the carton shows sign of damage, inspect...
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION 4. Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and See the USER MAINTENANCE INSTRUCTIONS section position the bath in the area of intended installation. of this owner’s manual, prior to installation, for humidity and mold prevention suggestions.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) Figure 3a Whirlpool System Export GROUND GROUND - GREEN WIRE NEUTRAL - WHITE WIRE AIR SWITCH ACTUATOR HOT - BLACK WIRE DEDICATED 240V,50 or 60 Hz GFCI PROTECTED SERVICE Dedicated 120V, 60 Hz GFCI Protected Service NOTE: USE THE ABOVE FULL SUPPORT BASE DIAGRAM FOR 240V, 50Hz PUMP MOUNT...
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) ELECTRICAL cord. Connect the pump to a GFCI (Ground Fault Circuit Interrupter) with the proper service: Electrical Power Supply: These instructions are written assuming 60Hz, 120V power supply. Special notations are Standard Equipment (120V,60Hz). also included for export versions of the equipment and power 120V, 20A, 60Hz electrical service with a service ground supply.
  • Page 5 INSTALLATION INSTRUCTIONS (cont.) FIELD INSTALLATION OF THE MICROSILK PUMP ® Figure 5 ASSEMBLY ® The Jason MicroSilk system has been factory assem- bled following ETL and IAPMO guidelines. For shipping ® purposes, on some bath models, the MicroSilk Pump As- sembly may be packaged separately and disconnected from the bath.
  • Page 6: Water Testing

    INSTALLATION INSTRUCTIONS (cont.) 6. Clamp the MicroSilk ® Drain Line to the MicroSilk ® Drain 4. Install the blower in the remote location. The remote mount locations’ ambient air temperature should remain Barb using the clamp provided on the tubing. Assure the MicroSilk ®...
  • Page 7 ® units provided on Jason baths This manual contains all of the information needed for are factory tested when assembled and again retested after the proper installation and operation of this Integrity ® installation on the bath. Soaking, MicroSilk ®...
  • Page 8 Automatic Purge Cycle Whirlpool Pump Fifteen minutes after the blower is stopped, the blower will The pump provided on Integrity ® Whirlpool baths is factory automatically start for two (2) minutes to purge and dry the tested when assembled onto the bath.
  • Page 9: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY SURFACE MAINTENANCE Warning: Avoid high humidity levels in your home. Areas with minor scratches or dull surfaces can be restored Mold, mildew, fungi and bacteria which may be by applying commercially available plastic polish (i.e. Novus harmful to health thrive in areas with continued high Plastic Polish No.
  • Page 10: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY REPAIRS MUST BE AUTHORIZED BY JASON BEFORE WORK IS STARTED. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER WARNING: Always turn off power at the mail electrical service panel when servicing the bath.
  • Page 11 TROUBLE SHOOTING GUIDE (cont’d) WHIRLPOOL PUMP SYSTEM SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTION a) No power to the pump unit. a) Reset circuit breakers and check GFCI. Check fuses and replace if bad. b) Pump motor is not plugged in. b) Make sure plug is fully inserted into the ourlet. Pump system won’t start.
  • Page 12 Troubleshooting Guide (cont.) MICROSILK PUMP SYSTEM ® SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTION MicroSilk system fails No power to the MicroSilk unit. Reset circuit breakers and GFCI if tripped. Check to operate. Motor is not plugged in. fuses and replace if bad. Check voltage at motor when control is on.
  • Page 13 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. This manual contains information and instructions for proper operation and maintenance of your therapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. WARNING: When using this unit, basic precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY DANGER:...

This manual is also suitable for:

MicrosilkAirmasseurIntegrity 7

Table of Contents