JASON Hydrotherapy forma Series Installation, Operation And Maintenance Instructions

JASON Hydrotherapy forma Series Installation, Operation And Maintenance Instructions

Advertisement

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
INsTallaTION, OPeraTION, aND MaINTeNaNCe
INSPECTION
Inspection of the unit prior to installation is the responsibility
of the installer. All components are factory assembled to the
bath and the unit is water tested and inspected prior to leaving
Jason International, Inc. If the carton shows sign of damage,
inspect the product before accepting and describe the problem
on the Bill of Lading. Note: Transportation and insurance
from Jason's factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of the carrier. If
damage is discovered, the carrier must be immediately notified
in writing with a request for a representative to inspect the
unit. Failure of the carrier to respond should be reported to
the seller and carrier. Always file a freight claim promptly.
The installer is responsible for insuring that the unit is free
from defects or shipping damage. In the event of a problem,
DO NOT install the unit. Jason International is not responsible
for damage that might have been avoided by inspection or
testing prior to installation.
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer. ALL
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE
MUST BE MADE PRIOR TO INSTALLATION. Inspect
CAUTION: DO NOT LIFT OR HANDLE THE BATH BY ITS PLUMBING.
OwNer's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
OwNer's MaNual
forma™ air-whirlpool Baths
plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the carton
until ready for installation.
Overall
Model
Dimension
L x W x H (in.)
AC630
72 x 36 x 22
AC635
72 x 42 x 22
CN550
60 x 60 x 22
DA500
60 x 60 x 20.5
RC630
72 x 36 x 22
RC635
72 x 42 x 22
RE525
60 x 30 x 20.5
RE527
60 x 32 x 20.5
RE553
66 x 36 x 22
RE630
72 x 36 x 22
PlaCe serIal NuMBer CarD wITh
PrODuCT CONfIguraTION IN ThIs BOx
Page 1 of 12
Table 1 - Specifications
Operating
Blower
Pump
Capacity
120v /
120v /
gal
240v hP
240v hP
AIR-WHIRLPOOL
45
1
1.5
56
1
1.5
66
1
1.5
55
1
1.5
50
1
1.5
58
1
1.5
38
1
1.5
39
1
1.5
47
1
1.5
53
1
1.5
Customer Service : 800.255.5766
49-1000-016
Date 04/08
Min. Size
floor
access
Loading
w x h
lbs/ft
2
(in.)
36 x 17
56.7 lbs
36 x 17
52.9 lbs
36 x 17
51.9 lbs
36 x 17
49.5 lbs
36 x 17
52.5 lbs
36 x 17
52.9 lbs
36 x 17
61.6 lbs
36 x 17
59.5 lbs
36 x 17
55.2 lbs
36 x 17
54.1 lbs

Advertisement

Table of Contents
loading

Summary of Contents for JASON Hydrotherapy forma Series

  • Page 1 “TO BE REMOVED FOR USE BY THE OCCUPANT.” Jason International, Inc. 49-1000-016 8328 MacArthur Drive Date 04/08 North Little Rock, AR 72118 www.jasoninternational.com OwNer’s MaNual forma™ air-whirlpool Baths INsTallaTION, OPeraTION, aND MaINTeNaNCe INSPECTION Inspection of the unit prior to installation is the responsibility plumbing and bath surface for missing or damaged of the installer.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS EQUIPMENT ACCESS the bottom of the bath. We recommend securing the blower and pump mounts to the floor with removable fasteners In accordance with Building Codes, service access to all for ease of servicing. therapy bath equipment, controls and electrical connections must be provided during installation (see Table 1 - Specifications WARNING: Any modification to the equipment is not on page 1 for minimum access size).
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) Figure 1A B R E A K E R B O X C O N N E C T IO N S L 2-W H IT E W IT H R E D M A R K 2 40 V N O C O N N E C T IO N F R O M H E A T E R...
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) GROUNDING IS REQUIRED. ELECTRICAL The unit should be installed by a qualified service representative NOTe: Verify the electrical service to match either the 120v and properly grounded. or 240v systems. WARNING: The electrical service to the GFCI must not be NOTe: The bath is designed for indoor use only.
  • Page 5 FEATURES OF THE AIR-WHIRLPOOL BATH STANDARD EDITION AIR-WHIRLPOOL BLOWER AND PUMP FEATURES TOUCHPAD FEATURES One main control touchpad mounted on the bath deck contains The Jason Standard Edition Air-Whirlpool bath provides both several icons used by the bather to control the blower, pump, an air bath and a whirlpool bath system.
  • Page 6 AIR-WHIRLPOOL CONTROL BOX CONNECTIONS STANDARD EDITION AIR-WHIRLPOOL Jason’s Standard Edition Air-Whirlpool system features the THE BLOWER CONTROL best in luxury bathing for the leisure bath industry. To assure that your bath functions properly, both the pump control box The blower and keypad must be plugged into the proper and the blower control must be properly connected.
  • Page 7 GENERAL OPERATING INSTRUCTIONS INTRODUCTION tested when assembled and again retested after installation on the Air-Whirlpool bath. This manual contains all of the information needed for the proper installation and operation of your Jason Air-Whirlpool bath. The STANDARD EDITION AUTOMATIC PURGE Air-Whirlpool bath has been designed to give you years of relaxing trouble-free service, provided the unit is maintained Fifteen minutes after the control has shut off and the bath is...
  • Page 8: Customized Settings

    OPERATING THE SIGNATURE EDITION AIR-WHIRLPOOL TOUCHPAD B L O W E R O N /O F F , M O D E S W H IR L P O O L O N /O F F , S P E E D C O N T R O L JASON B L O W E R S P E E D S S Y S T E M...
  • Page 9: Remote Control

    OPERATING THE SIGNATURE EDITION AIR-WHIRLPOOL TOUCHPAD (cont.) components. The test will begin by displaying the configuration REMOTE CONTROL number, followed by the software revision number. Next, The Signature Edition control system includes a waterproof the auxiliary control box will be tested to ensure proper IR floating Universal remote Control.
  • Page 10: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored Warning: Avoid high humidity levels in your home. Mold, mildew, by applying commercially available plastic polish (i.e. Novus fungi and bacteria which may be harmful to health thrive in areas with Plastic Polish No.
  • Page 11: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE ALL WArrAnTY rEpAIrS MUST BE AUTHOrIZEd BY JASOn BEFOrE WOrK IS STArTEd. If you believe the unit to be within the warranty period, you must contact Jason Customer Service at 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. FOr SErVICE, ALWAYS COnTACT YOUr dEALEr Or AUTHOrIZEd SErVICE CEnTEr.
  • Page 12: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS INsTruCTIONs PerTaININg TO The rIsK Of fIre, eleCTrIC shOCK, Or INJurY TO PERSONS. This manual contains information and instructions for proper operation and maintenance of your Air-Whirlpool bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. WARNING: When using this unit, basic precautions should always be followed, including the following: reaD aND fOllOw all INsTruCTIONs CarefullY...