"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
MADE IN THE U.S.A.
forma
InsTallaTIOn, OPeraTIOn, anD MaInTenanCe
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of lading.
InsPeCTIOn
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the Bill of
Lading.
NOTe: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier
to respond should be reported to the seller and carrier.
Always file a freight claim promptly.
The installer is responsible for insuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
Owner's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
Owner's Manual
and Designer Microsilk
®
Page 1 of 15
Baths
®
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACe
DAMAGe MUST Be MADe PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage, keep the bath in the
carton until ready for installation.
equIPMenT aCCess
In accordance with Building Codes, service access to
all hydrotherapy bath equipment, controls and electrical
connections must be provided during installation
(Recommended minimum 28" x 17" [71 x 43 cm]).
Insufficient access will hinder repair and maintenance.
Warranty service will not cover costs of providing
equipment access.
Jason offers an optional removable lateral skirt for all
rectangular baths. The skirts are available in matching
acrylic colors and provide convenient access to bath
equipment, as well as an excellent finished appearance.
The Specification Sheet for this bath contains additional
technical information. This sheet can be provided by your
dealer or accessed online at www.jasoninternational.com.
PlaCe serIal nuMBer CarD wITh
PrODuCT COnfIguraTIOn In ThIs BOx
49-1010-603
Date 11/13
Customer Service : 800.255.5766
Copyright © 2013 Jason International

Advertisement

loading
Need help?

Need help?

Do you have a question about the forma and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JASON Hydrotherapy forma

  • Page 1 49-1010-603 8328 MacArthur Drive Date 11/13 North Little Rock, AR 72118 www.jasoninternational.com MADE IN THE U.S.A. Owner’s Manual forma and Designer Microsilk Baths ® ® InsTallaTIOn, OPeraTIOn, anD MaInTenanCe If the carton shows sign of damage, inspect Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION assembly. At this time, considerations should be made for the position and mounting of the faucet set, as well as See the USeR MAINTeNANCe INSTRUCTIONS section of all related plumbing. this owner’s manual, prior to Installation, for humidity and mold prevention suggestions.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) Figure 3 Full Support Base FIeLD INSTALLATION To install the MicroSilk ® Pump Assembly to the bath, the follow- ing procedures must be followed. OF THe MICROSILK PUMP ASSeMBLY ® Note: Do not install the MicroSilk ® Pump Assembly further than ®...
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) 4. Clamp the MicroSilk ® Jet Line to the MicroSilk ® 6. Clamp the MicroSilk ® Drain Line to the MicroSilk ® Drain Discharge Barb using the clamp provided on the tubing. Barb using the clamp provided on the tubing. Assure Assure the MicroSilk ®...
  • Page 5 INSTALLATION INSTRUCTIONS (cont.) eLeCTRICAL Control Box 4. Standard/Premier edition MicroSilk ® (120v). The MicroSilk ® generator unit may be shipped electrical Power Supply: These instructions are written separate from the bath. Follow the instructions for the assuming 60Hz, 120v (or 240V for Signature Edition) power ®...
  • Page 6 INSTALLATION INSTRUCTIONS (cont.) 6. Signature edition MicroSilk ® Control Box. The If the MicroSilk ® generator unit is shipped separate from MicroSilk ® generator unit may be shipped separate from the bath, the MicroSilk ® pump’s power cord will need to be the bath.
  • Page 7 INSTALLATION INSTRUCTIONS (cont.) CLeANING WATeR TeSTING Remove all loose debris. Construction plaster or excess Before finishing the installation, it is recommended that the bath be grout can be removed with the use of a wood (edge) trowel. water tested and the plumbing tested for leaks. 2.
  • Page 8 mICROSILK CONTROL bOx CONNECTIONS ® STANDARD EDITION mICROSILK ® Jason’s Standard Edition MicroSilk system features the ® Figure 9 best in luxury bathing for the leisure bath industry. To assure that your bath functions properly, the MicroSilk ® pump control box must be properly connected. NOTe: For 120v systems, the power cord for the MicroSilk control box must be plugged into a 120v,...
  • Page 9 CONTROL bOx CONNECTIONS (cont.) SIGNATURE EDITION mICROSILK Figure 11 ® ® Jason’s Signature Edition MicroSilk system is the most advanced bath manufactured by Jason International, Inc. and features the ultimate in luxury bathing for the leisure ® bath industry. The MicroSilk control box must be properly connected for the bath to function correctly.
  • Page 10 OPERATING INSTRUCTION, FEATURES, AND CONTROLS INTRODUCTION pump 20 minutes after being activated. This manual contains all of the information needed for the Signature Remote Control proper installation and operation of your Jason MicroSilk ® In addition to the main control touchpad installed on the bath.
  • Page 11 STANDARD AND PREmIER EDITION mICROSILK TOUCHPAD ® ® MICROSILK LED Light MicroSilk™ On/Off ® Figure 12 LeD Light Icon The Jason Standard and Premier Edition MicroSilk ® touchpad is used to access all of the functions of the pump The LED Light icon is used to operate an LED light (if control.
  • Page 12 SIGNATURE EDITION mICROSILK TOUCHPAD ® For Diagnostic Functions For Diagnostic Functions LED Light ® MicroSilk™ On/Off IR for Remote Display Panel Figure 13 Menu Instructions The Jason Signature Edition MicroSilk ® digital touchpad is used to access all the functions of the MicroSilk ®...
  • Page 13: User Maintenance Instructions

    USeR MAINTeNANCe INSTRUCTIONS HUMIDITY CLeANING With minimum care, your acrylic-surfaced bath will retain WARNING: Avoid high humidity levels in your home. its high-luster finish for many years. For regular cleaning Mold, mildew, fungi and bacteria which may be use Jason Bath Cleaner or a mild NONABRASIVe liquid harmful to health thrive in areas with continued high detergent solution (i.e.
  • Page 14: Troubleshooting Guide

    TROUbLE SHOOTING GUIDE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY RePAIRS MUST Be AUTHORIZeD BY JASON BeFORe WORK IS STARTeD. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER WARNING: Always turn off power at the main electrical service panel when servicing the bath.
  • Page 15: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS InsTruCTIOns PerTaInIng TO The rIsK Of fIre, eleCTrIC shOCK, Or InJurY TO PersOns. This manual contains information and instructions for proper operation and maintenance of your hydrotherapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. warnIng: when using this unit, basic precautions should always be followed, including the following: reaD anD fOllOw all InsTruCTIOns CarefullY...

This manual is also suitable for: