Installers Checklist - CMA Dishmachines CMA-L-1X Owner's Manual

Cma cma-l-1x: owner manual
Hide thumbs Also See for CMA-L-1X:
Table of Contents

Advertisement

Getting Started

2.2.4. Installers Checklist

Dishmachine checked for concealed damage
Hot water supply is 140° F (60 C)
Incoming water supply line is ½" minimum
Supply circuit breaker for machine is properly sized (20 amp)
Service voltage and phase type are correct to machine data plate
Drain hose is installed with adequate air gap
Dishmachine is properly grounded
Dishmachine is properly leveled
Machine circuit breaker is labeled "DISHWASHER"
Machine has been connected with correctly sized wire (12 gauge
minimum)
7
Page
MODEL L-1X & L-1X16 Installation & Operations Manual Rev. 1.15