Pylontech Force-L1 Product Manual page 10

Lithium-ion phosphate
Hide thumbs Also See for Force-L1:
Table of Contents

Advertisement

Status
System Status: blue means working normally; Orange means protection or failure.
Blue, slow flashing.
Blue, lighting.
Orange, slow flashing.
Orange, lighting.
Battery Module Status
Battery Module Status: blue means working normally; Orange means protection or failure
Blue, slow flashing.
Blue, lighting.
Blue, light once.
Orange, slow flashing.
Orange, lighting.
System Capacity
Indicate the system SOC.
Blue, slow flashing.
Blue, flashing.
Blue, lighting.
Remark: Slow flashing: 1.5s ON/0.5s OFF. Flashing 0.5s ON/0.5s OFF.
Fast flashing: 0.1s ON/0.1s OFF.
Power Relay CLOSE. Alarm exist but can work continue.
Power Relay CLOSE. Normal.
Power Relay OPEN. Normal protection, can recover on
its own (Over Voltage, Under Voltage, etc.).
Power Relay OPEN. Important protection, failure, lost
efficacy etc. Or failed to assign address.
Alarm exist but can work continue.
Normal.
1~n LED lights on one by one, for address distribution.
Module offline.
Module protection, failure, etc.
Each LED indicate 25%SOC. Idle
Each LED indicate 25%SOC. Discharge
Each LED indicate 25%SOC. Charge
8 / 12
19P1FL0801

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

48v518ah

Table of Contents