Installation - Nibe VPB 500 UK Installation And Maintenance Instructions Manual

Hide thumbs Also See for VPB 500 UK:
Table of Contents

Advertisement

General
VPB 500 UK is a water heater which is suitable for con-
nection to heat pumps.
The water tank consists of a steel jacket, with a copper
lining to protect against corrosion. The water heater is
equipped with a copper coil of finned tube.
The water heater is designed and manufactured for a
maximum cut-off pressure of 6 bar. Maximum permitted
temperature is 95°C.
The insulation is polyurethane, which provides excellent
heat insulation. The insulation and outer shell of grey
plastic is easy to remove.
The VPB is equipped with a immersion heater connec-
tion and a submerged tube for control of water heating.
Removing part of the insulation
The backside of the insulation on VPB can be removed
in order to facilitate handling in confined spaces (this
will save 50 mm).
1.
Remove all screws along the joining plates.
2.
Lift off the top cover.
3.
Pull the insulated jacket halve straight off.
Carry out assembly in reverse order. If the screws are
difficult to fit in the old holes, the plate can be turned
upside down, which produces new holes in the insu-
lated jacket halves.
Ø 760 mm with insulation
This appliance can be used by children aged from 8 years and above and per-
sons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concer-
ning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Rights to make any design or technical modifications are reserved.
©NIBE 2015.

Installation

The hot water heater is unscrewed from the pallet and
lifted into position, use the lifting eyes if necessary. The
water heater must be installed in an upright position.
The four feet are height-adjustable. VPB 500 UK can be
equipped with the following immersion heaters, con-
nection dimension G2. When installing the water heat-
er, ensure that there is enough room for removing the
immersion heater in front of the connection area, see
following table.
Fit the supplied cover discs before pipe installation. The
cover discs, with self-adhesive backs, must be fitted on
the relevant connection by pushing them over the con-
nections.
All connections (including those not used) must be insu-
lated to minimise idle losses.
This installer manual must be left with the customer.
Immersion heater Power output
IU 31
IU 33
IU 34
IU 36
IU 39
IU 310
IU 311
50 mm less without insulation
VPB 500 UK
Free space
1500 W
250 mm
2250 W
260 mm
3000 W
280 mm
4500 W
400 mm
6000 W
400 mm
7500 W
400 mm
9000 W
400 mm