The Keypad Buzzer

2.
The keypad includes a buzzer that is used for audible signalling and verification of certain keypad functions.
There are 7 possible volume settings: loud being the default setting. To program the keypad volume, use Table
4.
Table 4: Keypad Buzzer Settings
Key Entry
[#] [3]
[#] [2]
[#] [1]
[#] [0]
To change the volume (for this example to the "soft" setting) press the [#] and [1] keys simultaneously for 1
second (long press). After a 1-second time lapse, the keypad will respond with a beep at the new volume
setting. This is a keypad specific setting, and applies to the keypad that this operation is performed on.
All zones programmed as Chime or Buzz zones, will sound with a loud buzz regardless of the keypad volume set
above.

Arming the Alarm

3.

Away Arm

LED Keypad
1. Ensure that the READY LED is on. If not, check that all protected doors and windows are closed and that
all movement has ceased in areas covered by motion detectors. If necessary, close the front door.
2. Press the [#] key.
3. Enter a valid [USER CODE]. If an incorrect code is entered, the keypad buzzer will beep three times. In
the event of an error press the [#] key and re-enter the code.
4. The READY LED turns off, and the ARM LED will come on and the keypad buzzer will beep repeatedly for
the duration of the exit delay. Any bypassed zones will be indicated by a steady on zone LED.
5. Leave only via a designated exit route (leaving by any other route can set off the alarm). The panel will
arm at the end of the exit delay.
LCD Keypad
1. Ensure that the LCD display reads 'Ready to Arm' alongside the partition number being armed. If not,
check that all protected doors and windows are closed and that all movement has ceased in areas
covered by motion detectors. If necessary, bypass any required zones and close the front door.
2. Press the [#] key.
3. Enter a valid [USER CODE]. If an incorrect code is entered, the keypad buzzer will beep three times. In
the event of an error, press the [#] key and re-enter the code.
4. The ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay. The LCD
display will read 'Exit Delay' alongside the partition number that is being armed. Any bypassed zones will
be displayed on the LCD display as solid text. Any violated zones will be displayed on the LCD display as
flashing text. To scroll through zones which have been bypassed or violated use the [PANIC] and [MED]
keys.
5. Leave only via a designated exit route. The panel will away arm at the end of the exit delay, if any
enter/exit zone is violated, e.g. the front door.
6. Once the panel has armed, the LCD display will read 'Armed' alongside the partition that has been
armed.
Q uic k Aw ay Ar m
If this function is enabled, it is possible to AWAY arm by holding down the [1] key until the arming process
begins.
NOTE: If the partition is already STAY armed, this key will initialise AWAY arming. It is therefore possible to
change directly from STAY arm to AWAY arm.
[#] WITH any key from [0] to [6] for 1 second
Keypad Buzzer Sound
Loud (Default setting)
Medium
Soft
Click
[#] [USER CODE] (Leave via Entry/Exit Zone)
[#] [USER CODE] (Leave via Entry/Exit Zone)
Hold down the [1] key until the beep
700-398-01J X-Series User Manual Issued for version 2.8x
Key Entry
Keypad Buzzer Tone
[#] [6]
2kHz (High)
[#] [5]
1kHz (Medium)
[#] [4]
440Hz (Low)