Setting The Topology And The Loop Id (For Direct Host Connections); Setting The Topology (For Connections Via Fc Switches) - Fujitsu ETERNUS LT260 User Manual

Tape library
Hide thumbs Also See for ETERNUS LT260:
Table of Contents

Advertisement

Chapter 2 Setting the LT260
2.2 Settings for Fibre Channel Connections
When connecting the LT260 to a Brocade 16G FC switch (BR65xx/EBRDC8x) with a link speed of 8Gbit/s,
apply firmware version v7.3.0c or later to the FC switch and perform the following settings.
For the FC switch
(1)
For the port to which the LT260 tape drive is connected, fix the speed to 8Gbit/s with the
"portcfgspeed" command.
(2)
For the port to which the LT260 tape drive is connected, disable the DFE function (*1) with the
"portcfgnondfe" command.
*1:
For the LT260
(3)
Fix the link speed of the LT260 tape drive to 8Gbit/s.
These settings are not required if the LT260 is connected to a Brocade 32G FC switch (Brocade G610/G620/
G630/X6-4/X6-8) because the LT260 automatically recognizes the link speed.
2.2.2

Setting the Topology and the Loop ID (for Direct Host Connections)

The following settings are required for direct host connections:
If the Fibre Channel card of a host is an LPe3xxxx series, a PY-FC33x/PY-FC35x series,
an MC-0JFCFx/MC-0JFCGx/MC-0JFCMx/MC-0JFCNx series, or an SP1X7FBC2F
Port Type:
If the Fibre Channel card of the host is a series other than the above
Port Type:
Addressing mode:
Loop ID/ALPA:
For more details about the settings, refer to "FUJITSU Storage ETERNUS LT260 Tape Library User's Guide
-Panel Operation-".
2.2.3

Setting the Topology (for Connections via FC Switches)

The following settings are required for connections via FC switches.
For more details about the settings, refer to "FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Panel
Operation-".
Port Type:
Although the "Auto" setting can be selected, select one of the fixed values described above.
FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Server Connection-
The Decision Feedback Equalization (DFE) function corrects signal noises on the receiver. Disable this
function because it may prevent the port connected to the LTO drive from correctly recognizing the
signal.
Fabric (N/F)
Loop(L)
Hard
Any value
Fabric(N/F)
Copyright 2019 FUJITSU LIMITED
23
P3AM-8812-07ENZ0