Chapter 4 Setting Backup Software
4.5 NetVault
12
13
14
15
16
17
FUJITSU Storage ETERNUS LT260 Tape Library User's Guide -Server Connection-
Enter "2" and then press the [Enter] key.
"2) Cleaning..." is selected. The Cleaning screen appears.
Set the Cleaning items as shown below.
Automatic Cleaning Supported
ON (the default setting is "ON")
Barcode Prefix(es) of cleaning media
Set with the character string that is on the label of the cleaning cartridge.
Cleaning Slots
The slot numbers where the cleaning cartridges are to be stored.
Enter "b" and then press the [Enter] key.
The Changer Configuration screen appears again.
In the Changer Configuration screen, enter "s" to save the settings.
Enter "q" to quit the Drive Configuration screen.
In [Manage Devices] of NetVault WebUI, click the [Manage Library] button of the target library
to switch to the Tape Library Management screen.
Reboot the library by clicking the [Restart] button at the bottom right of the page.
The new settings are applied after the library is rebooted.