Setting the SCSI ID

3.4
Setting the SCSI ID
You set the SCSI ID (bus address) using the coding jumpers of the installed
backup unit involved.
The SCSI IDs must be unique (assigned only once in the SCSI string) and are
freely selectable from SCSI ID 0 to SCSI ID 6 (SCSI ID 7 is always used by the
host adapter).
I
There is an adhesive device label (see figure 2 on page 20) on the back
of the storage subsystem. Enter the designation of the device type and
the SCSI ID of the installed backup units on this label.
This makes it easier to identify the backup units.
3.5

Connecting the storage subsystem

The ports are on the rear of the subsystem (figure 2).
Figure 2: PRIMERGY S10: ports
(1) SCSI system port: 68-pin SCSI connector (SCSI input) for the connection
to the host adapter (SCSI-LVD/SE controller).
(2) SCSI system port: 68-pin SCSI connector (SCSI output) for the "daisy-
chain" connection to a secondary storage subsystem.
(3) Power OUT, not activated, maximum 1,5 A.
(4) Voltage switch 115 V/230 V.
(5) Insulated socket for power connection.
20