Repair
Driving gear
u Install a cap on the sample container.
u Tighten the sample container cap by hand.
u Install a new screw plug into the lower sample opening 2.
Information
Always replace the screw plug.
u Tighten the screw plug to torque.
page 108.)
u Fill in the sample form delivered with the sampling kit.
u Place the sample container and form into the padded envelope and send them for analysis.
Specific values
Not applicable.
Tightening specifications
Fig. 118: Screw plugs for silicon oil collection
1
-
Tab. 27: Tightening specifications table
*Lubricants:
MG = Molykote G-n-plus
MW = Castrol Optimol paste white T
MH = Molykote HSC
108
Key
Screw specifications
Screw plug
© 2021 by Kohler Co. All rights reserved.
(For more information see: Tightening specifications,
-
Service and Repair Manual
Torque
± 5%
No
1 15 Nm
-
11 ft-lb
KD83V16 33525088901_2_1 EN_US
Angle (°)
± 5°
-