Use the turning device to rotate the crankshaft.
page 269.)
u Remove the cap from one end of the sample container.
Information
Place the sample container cap in a safe place.
u Make sure that the lower sample opening 2 is clean and free from dirt, grease, and engine oil.
u Remove the plug from the lower sample opening 2.
u Immediately install the sample container into the lower sample opening 2.
u Tighten the sample container by hand, then loosen it by one turn.
Information
Do not use any tool to tighten the sample container.
u Remove the cap from the other end of the sample container.
Information
Place the sample container cap in a safe place.
u Make sure that silicon oil flows from the torsional vibration damper into the sample container.
Information
If the flow of silicon oil is very slow, open the upper sample opening 1.
u When the sample container is 75% full, install a cap on the end of the sample container.
u Tighten the sample container cap by hand.
Information
Do not use any tool to tighten the sample container cap.
u Install a new screw plug into the upper sample opening 1 if it has been opened.
Information
Always replace the screw plug.
u Tighten the screw plug to torque.
page 108.)
u Remove the sample container from the lower sample opening 3.
Information
Make sure that silicon oil does not leak from the sample container.