Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a dif
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they a
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will rece
same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock fu
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be t
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Basic Set Level
Setting the BASIC command value to turn on the light
Size: 1 Byte, Default Value: 255
Setting
0
1 - 100
254
Parameter 3: PIR Sensitivity
PIR sensitivity settings.
Size: 1 Byte, Default Value: 80
Setting
0
1 - 99
Parameter 4: Light Threshold
Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn
light. 0 means turn off illumination detected function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
Size: 1 Byte, Default Value: 99
Setting
0
1 - 100
Parameter 5: Operation Mode
Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0
http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1B
Maximum Nodes
Description
8
Receiving the report message, like triggered event, temperature, illumination etc.
Light control, the device will send the "Basic Set" command
8
Description
turn off the light
the light strength.
turn on the light.
Description
disable the PIR motion.
1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected lon
but if there is more noise signal in the environment, it will re-trigger too frequency.
Description
turn off illumination detected function.
1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn
light.