Preventive Inspection Maintenance; 90 Day Or 150 Hour Checklist - Snorkel MHP 15 J Maintenance And Repair Parts Manual

Engine powered gasoline battery electric
Table of Contents

Advertisement

Preventive inspection maintenance

90 day or 150 hour checklist

OK OK - No Service Required
Corrective Action Required
X
Corrected, (Record description of corrective action).
Inspection Procedures Codes
(1) Weld cracks, dents and/or rust
(2) Installation
(3) Leaks
(4) Operation
(5) Condition
(6) Tightness
(7) Residue buildup
(8) See placards and decals inspection chart
Check
Chassis
Structural (1)
Tires (5)
Tire pressure (5)
Hydraulic tubes and hoses (3,5)
Decals and placards (2,8)
Wheel nuts (6) Torque 95lbft 130NM
Battery disconnect switch (4)
Lubrication points
Pins, pin keepers (2)
Turntable
Structural (1)
Swivel mount assembly (2,3)
Hydraulic tubes and hoses (3,5)
Cowling (5,6)
Wire harness (2,5)
System pressure (Max 2500 psi)
Lubrication points
Emergency bleed down valve (4,3)
Engine (2,4)
Engine charging system (4)
Engine air filter (5)
Hydraulic pump (4)
Engine oil (5)
Electric choke (4)
Hydraulic oil reservoir (2,3,5)
Hydraulic oil reservoir filler/breather cap (2,6)
Hydraulic oil reservoir fluid level (5)
Hydraulic oil return filter (3,4)
Pins, pin keepers (2)
Lower Booms
Structural (1)
Boom lift cylinder pin caps (2,6)
Boom lift cylinder and holding valve (3,4)
Jib cylinder pin (3,4)
Hydraulic tubes and hoses (3,5)
Electrical Wires (5,2)
Upper Booms
Structural (1)
Electrical wires (5)
Jib cylinder pin caps (2,6)
Jib cylinder and holding valve (3,4)
Hydraulic hoses and tubes (3,5)
Decals and placards (2,8)
Platform rotator (Optional) (3,4)
MHP15J – 11995B
Serial Number
Platform rotation holding valve (3,4)
Rotator mounting bolts (2,6)
Platform
Structural (1)
Decals and placards (2,8)
Platform gate (4)
Hydraulic tubes and hoses (3,5)
Platform mounting bolts (2,6)
Correct operator's manual in document holder (2)
OK
X
Battery
Battery terminals (6,7)
Battery electrolyte level (5)
Fuel Tank
Fuel tank (3,5)
Fuel tank cap (2,3,4,5)
Ground Control Station
Station selector switch - ground controls
platform controls DO NOT work (4)
Station selector switch - platform controls
ground controls DO NOT work (4)
Cold start (4) Choke
Keyed master switch (4)
Boom speed rheostat switch (4)
Turntable rotation (4)
Upper boom lift UP - DOWN (4)
Lower boom lift UP - DOWN (4)
Jib boom lift UP - DOWN (4)
Emergency stop (4)
Platform Control Station
Foot switch (4)
Foot switch, functions operate when engaged (4)
Anti-restart switch (4)
Cold start (4) Choke
Boom speed rheostat switch (4)
Turntable rotation (4)
Upper boom lift UP - DOWN (4)
Lower boom lift UP - DOWN (4)
Jib boom lift UP - DOWN (4)
Emergency stop (4)
Optional Equipment
Air line to platform (2,4)
Dual fuel system (2,4)
Platform work lights (2,4)
Platform rotation (4)
Maintenance Information
Check
OK
X