MOUNTING THE LIMIT SWITCH IN AN EXISTING EQUIPMENT

When the AMD limit switch is to be fitted to an existing device, please follow these steps.
9.1

Kit contents

The kit contains the following elements:
Quantity
1
2
1
1
2
2
2
In the kits, the gaskets (5) and the blanking plugs (7) are not provided as loose parts. They
are incorporated in the cable glands (6).
9.2

Preparing the kit

Remove the cover, unscrewing the four screws M4.
Slide the scale plate in the direction indicated in the figure, until it is released from the slot.
Blanking plug (7)
Ensure that the gaskets (5) are placed in the thread of the gland (6). If not, they should be
placed. Remove the plugs from the indicator box with a flat screwdriver and replace them by
the two cable glands.
The cable glands that are not expected to be used should be left with the blanking plug (7)
placed to preserve watertight.
AMD kit
AMD limit switch circuit
Self tapping screw DIN7982 B-2,2 x 9,5 Nº2 A2
AMD vane
Self tapping screw DIN7982 B-2,2 x 9,5 Nº2 A2
Gasket
Cable gland IP68
Cable gland blanking plug
Material
Cable glands (6)