The differential pressure between P
mbar depending on the model. This differential pressure is calculated for the proper
operation of the flow rate regulator.
6.1

Regulation curves

The flow curves show the relationship between
pressure P
in the RCA regulator.
2
The different flow rates are adjusted by means of the regulating valve of the flowmeter. The
counter pressure P2, in these cases, corresponds to the atmospheric
Q air (Nl/h)
P0 = inlet pressure RCA regulator (low flow)
The dotted line shows the variation of flow without the action of the constant flow
regulator.
With constant flow regulator, variations of 100% in the inlet pressure P
variations of flow of less than 1%.
and P
2 should always be
0
the inlet pressure P
13
higher than 350-450
and the counter
0
pressure.
variation without
regulator
variation with
regulator