Technical Description Of The Burner; Burner Designation; Models Available; Technical Data - Riello Gulliver BGK3 Installation, Use And Maintenance Instructions

Light oil burners
Hide thumbs Also See for Gulliver BGK3:
Table of Contents

Advertisement

Available languages

Available languages

4

Technical description of the burner

4.1

Burner designation

Series :
B
Fuel :
B
G
4.2

Models available

Designation
BGK3
4.3

Technical data

Type
Output - Thermal power
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Operation temperature
Atmospheric pressure
Technical description of the burner
Low NOx burner
G
Light oil
Variation :
K
Size
K
3
1/230/50
Electrical supply
1/230V/50Hz
Cone shaped head
Electrical supply to the system :
Code
20012189 - 20015628
3.8 - 6.15 Kg/h – 45 - 73 kW
Light oil, viscosity 4 - 6 mm
Single phase, ~ 50Hz 230V ± 10%
Run current 1.8A – 150W
2800 rpm –
Secondary 8 kV – 16 mA
Pressure: 8 – 15 bar
-10°C + 40 °C
Max. 1013 mbar
7
GB
1/230V/50Hz
375T1
2
/s a 20 °C (Hi = 11.86 kWh/kg)
294 rad/s
6,3 F
0,46 kW
20013962