Proceed as follows (see Fig. 60 page 98):
• Release the cap. Unhook right and left side panels and extract it from its housing.
• After these operations you can have access at the following components: geared motor (3), ignition
plug (5), ambient fan (8), fume fan (7), ambient probe (10), fume probe (9), thermostat (6), electronic
board (1), pressostat (4).
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor
(3) and to extract it, unscrew the two screws lying under the geared motor of the auger, remove the
hand rejector inside the hopper and then unscrew the inner bolt of the auger. To assembly proceed at
the contrary.
VENUS - GIOIA
Fig. 59 - Shutter with the fuse to remove
EN
97