Cadel VENUS Installation, Use And Maintenance Manual page 91

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 53
ALARM
CAUSE
Empty hopper
The burning pot has not
been cleaned
It has not reached the
ignition threshold to the
probe
Faulty ignition plug
AL 5 - NO
IGNITION
Too severe external
temperature
Humid pellet
Blocked thermal probe
Faulty mother board
AL 6 - NO
Empty hopper
PELLET
Boiler overtemperature
The ambient exchanger
fan does not work
AL 7 -
THERMAL
Temporary blackout
SAFETY
Faulty manual reset
thermostat
Faulty mother board
VENUS - GIOIA
SOLUTION
Full the hopper.
Clean the burning pot.
Clean the burning pot and start the stove up again.
(If the problem persists please contact an Authorized
Technician).
Replace the igniter resistance.
Start the stove up again,
Assure you that the pellets are stored in a dry place.
Replace the thermal probe.
Replace the mother board.
Fill the hopper.
Let the stove cooling. (If the problem persists please
contact an Authorized Technician).
Replace the ambient fan.
The lack of tension during running implies boiler
overheating and manuel reset thermostat
intervention. Leave it cooling, reset and start the
stove up again.
Replace the manual reset thermostat.
Replace the mother board.
INTERVENTION
EN
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gioia

Table of Contents