ALARM
CAUSE
Obstructed exhaust
EN
Faulty exhaust fan
Obstructed outlet
connector
AL 8 - FAILURE
DEPRESS
Faulty pressostat
Faulty mother board
Extreme chimney lenght
Adverse weather
conditions
The fire door is not
correctly closed
AL 9 - OPEN
DOOR
Fire door microswitch
faulty or out of order
92
SOLUTION
The exhaust chimney is partially or tatally obstructed.
Please contact a Specialized Stove-repairer who
checks the stove exhaust up to the chimney pot.
Please have it immediately cleaned. It can be
harmful to health to run the stove with the obstructed
chimney.
The pellets can burn also thank to chimney flue
depression without the aid of the exhaust fan. Have
the exhaust fan immediately replaced. It can be
harmful to health to run the stove without exhaust
fan.
Clean the outlet connector.
Clean the pressostat.
Replace the mother board.
Contact a Specialized Stove-repairer and check
that the exhaust chimney is in accordance with the
regulations: see CHIMNEY FLUE page 56.
In case of strong wind there can be a negative
pressure to the chimney. Check it and start the stove
up again.
Close the fire door correctly and check if the gaskets
are damaged. (In this case have it replaced by an
Authorized Technician).
Replace the fire door microswitch.
INTERVENTION
VENUS - GIOIA