PROBLEM
EN
Fire extinguishes
and stove stalls
Running stove
and display
showing "FIRE
POT CLEANING"
Flames are weak
and orange,
pellet does not
burn properly
and the glass
blackens
Heat exchanger
fan keeps turning
even when the
stove has cooled
94
CAUSE
SOLUTION
Empty hopper
Fill the hopper.
Auger blocked
by a foreign
Clean the auger.
object (for
example nails)
Poor quality
Try with other pellet types.
pellet
Pellet loading
value too law
Adjust pellet load.
"phase 1"
Check if there is
an active alarm
Have the stove overhauled.
"ACTIVE ALARM"
Automatic
At idling stove and at maximum fume suction NO
burning pot
PROBLEM!
cleaning
Check the following inscription: probable obstructions
for combustion air inlet from the stove back or bottom;
Insufficient
obstructed holes of the burning pot grid and/or burning
combustion air
pot with too ash. Have the fun blades and its screw
cleaned.
The exhaust chimney is partly or fully obstructed.
Obstructed
Contact an expert stove-repairer to check the exhaust
exhaust
up to the chimney pot. Please clean it immediately.
Obstructed stove
Clean the stove inner.
Pellet can burn also thank to chimney flue depression
Exhaust fan out
without exhaust fan. Have the exhaust fan replaced
of order
immediately. It can be harmful to health to run the stove
without fume exhaust fan.
Faulty fume
temperature
Replace the fume probe.
probe
Faulty mother
Replace the mother board.
board