Settings Lock; Reset - Datavideo DVK­100 Mk II Instruction Manual

Dual channel chroma keyer
Table of Contents

Advertisement

Settings Lock 
Once you have set all the parameters of the DVK­100 set to produce the perfect effect from both of your 
cameras you can lock the settings. Once locked none of the DVK­100 front panel controls will respond. 
To lock the DVK­100 front panel, press and hold either the CAM­1 or CAM­2 button for two seconds. The 
button will be illuminated amber, instead of the usual red, and the front panel will be locked. 
To unlock press and hold the CAM­1 or CAM­2 button again for two seconds, until the button returns to 
being illuminated red. 
All of the settings are non­volatile, so they are held in memory when the DVK­100 is switched off. When the 
DVK­100 is switched on all the parameters will be as you left them. 
Reset 
If you want to return all parameters of the CAM­1 or CAM­2 channels to factory default, press 
the respective button CAM­1 or CAM­2 so that it is illuminated red. 
Then press the Reset button. After about two seconds all parameters of the channel will be 
restored to factory default.
With the window size adjusted correctly we can set the Green Keying 
Level, Density, Edge, Subject Density and Spill, to produce the finished 
shot. 