4. Route the control trunk-line through the
grommeted opening. Connect the ½" air line
via the JIC fitting on the end of the air tank,
and connect and secure the weather proof
connectors. The plugs are all differentiated
to ensure that they cannot be mis-
connected.
5. Leaving the unit in the preliminary position,
connect the ground cable to the unit battery,
check all fluid levels. Replace the front
access panel and close the unit hood.
6. Refer to Figure 4-6 for remote-mounted fuel
pump: Open the bleed nut shown to siphon
off any air in the line. Turn on the pump,
allow air to escape, and tighten the nut when
all air is out of the system (fuel begins to leak
out).
7. Move the unit into its final location for
mounting, while positioning the control trunk
line and all other connections.
8. Bolt the machine down with four ½" bolts
inserted from the bottom. Note: See Figure
4-1 for location space requirements.
9.
Start the unit and fully test all functions. Warm
the unit to full operating temperature. After
the unit has cooled, check all fluid levels and
add as needed.
®
Figure 4-6: Fuel Line Bleed Nut (for
090012-OP_r0
SECTION 4: INSTALLATION
Figure 4-5: Lifting Bail Location
remote mounting)
PAGE - 41