Symptom
Appliance starts and stops frequently
when operating in the mode
Slow or smoky start-up and/or lazy
flame
Convection blower fails to start
Convection Blower fails to shut off
Exhaust blower fails to start and/or
red flashes 6X – indicating a exhaust
encoder alarm.
Exhaust Blower fails to shut off
Feed Motor fails to shut off
Convection Blower makes noise
Igniter does not turn off
27
Possible Cause
Area where the thermostat is placed
affects temperature.
Thermostat located in tight spaces
effecting the on/off cycling of the
appliance.
Thermostat SWING function is set
too low
Dirty fire pot, exhaust path, and/or
venting system.
Not enough combustion air
Misaligned igniter
Wet fuel or poor quality fuel
Convection Blower is jammed
Not electrically connected
Blower is defective
Exhaust probe not sensing correct
temperature
Control board is defective.
Wire short between blower and
ground - Control board is defective
Exhaust blower is jammed
Not electrically connected
Blower is defective
Control board or dial control is
defective.
Wire short between blower and
ground - Control board is defective
Wire short between ground and:
feed motor, vacuum switch, hopper
switch, or safety snap disc
Control board is defective
Convection blower is dirty causing
an out-of-balance condition
Wire short between igniter and
ground – Control board is defective
7082-803B
Corrective Action
Check thermostat proximity to doors and windows
Inspect thermostat location and make sure it is not
close to a surface that heats and cools quickly.
Raise the thermostat swing temperature (see
function section for instructions)
Clean entire appliance including: fire pot, ash build
up in firebox, fire pot area, behind baffle, firebox,
exhaust blower, venting, and ash pan.
Adjust the trim (see trim adjustment section)
Center the igniter in the chamber
Replace wood pellet fuel
Clean and un-jam the blower
Connect the blower wires to its respective power
wires
Replace blower
Secure the exhaust probe to exhaust blower housing
– keeping its wire away from hot surfaces
Replace control board
Repair wire and replace control board
Clean, and undo jam from the blower
Connect the blower wires to its respective power
wires
Replace blower
Unplug dial control, if exhaust blower runs, dial
control is defective. If exhaust blower does not run
with dial control unplugged, replace control board.
Repair wire and replace control board
Repair wire(s) and replace control board
Replace control board
Clean blower impellers
Repair wire and replace control board