Led Color Coding Chart And Explanation - Quadra-Fire TREKKERI-MBK Owner's Manual

Hide thumbs Also See for TREKKERI-MBK:
Table of Contents

Advertisement

P. LED Color Coding Chart and Explanation
The number of flashes between pauses is per one second unless otherwise indicated.
LED
No. of Flashes
Color
between pauses
Steady ON while
priming feed tube
Green
(max time
2 min utes)
1x every 2
Green
seconds
Blinks
Green
Continuously
Green
1X
Green
2X
Green
3X
Green
4X
Green
5X
Blinks
Amber
Continuously
Red
1X
Red
2X
Red
4X
Red
6X
Red
8X
Table 13.1
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Fire pot floor open.
Do NOT store fuel:
• Closer than required clearances to
combustibles to appliance
• Within space required for loading or ash
removal.
13
Description
Feed Motor is running
continuously.
(priming the feed tube)
Appliance is on standby
Appliance is in the start
up/ignition sequence or in
shutdown.
Stage 1: Low heat
Stage 2: Med-Low heat
Stage 3: Med heat
Stage 4: Med-Hi heat
Stage 5: Hi heat
Appliance is in the
shutdown sequence.
Empty Hopper Alarm
Exhaust Probe Alarm
Missed Ignition
Encoder Alarm
Exhaust Over
Temperature Alarm
WARNING
Notes
When priming the feed system and filling the fire pot, DO
NOT OVERFILL Fire pot FOR IGNITION. The appliance will
automatically go into start up following the prime function.
To start appliance, follow start up sequence.
During shut down, the blowers will shut off when the exhaust
temperature has cooled.
BTU Range: 14,620 - 19,694
BTU Range: 22,102 - 23,506
BTU Range: 30,778 - 32,680
BTU Range: 38,576 - 42,914
BTU Range: 49,830 - 52,460
During shut down, the blowers will shut off when the exhaust
temperature has cooled.
This alarm is caused by the fire going out from lack of fuel.
Reset by turning to "OFF" then turn dial to desired setting.
Failed component error. See troubleshoot ing section for
more information.
There are a total of 2 tries per ignition sequence. If after
2 tries there is no rise in exhaust temperature this error
will occur. See the troubleshooting section for addi tional
information.
Failed Component Error: Exhaust Speed Sensor. See
troubleshooting guide for more information
See troubleshooting guide for more information.
7082-803B
Average: 19,054
Average: 22,735
Average: 31,603
Average: 40,665
Average: 51,528
06/21