VOLTAGE MONITORING
EVM-05C
SETTING DELAY TIME (OND/OFD) FOR FREQUENCY:
Press SET button for 3 secs.
SET
Find SP menu by
scrolling UP/DOWN
buttons.
Press SET
SET
button.(SP Hi is
displayed)
Find SP FrEq menu by scrolling
UP/DOWN buttons.
Press SET button.(Frq Hi is
SET
displayed)
Find Frq Ond/Frq Ofd menu by scrolling UP/DOWN
buttons.
SET
Press SET button
Enter 1st digit value by scrolling UP/DOWN buttons
(If you set 1st digit value incorrect, you can set again by pressing ESC
button.)
SET
Press SET button
Enter 2nd digit value by scrolling UP/DOWN buttons
(If you set 2nd digit value incorrect, you can set again
by pressing ESC button.)
Press SET button
SET
Enter 3rd digit value by scrolling
UP/DOWN buttons
digit value incorrect, you can set again by
pressing ESC button.)
Press SET button
SET
Enter decimal digit value by scrolling UP/DOWN buttons
(If you set decimal digit value incorrect, you can set again by pressing
ESC button.)
Press SET button after you enter the value
SET
Press ESC button one by one until SAU SEt yES is
ESC
displayed.
Press SET buton while SAU SEt yES is displayed.
SET
PHASE SEQUENCE
EVM-05C checks phase sequence.If the phase sequence is
altered by any reason, L1 L2 L3 LEDs blink, the output relay 2
activates immediately and Out 2 LED turns off.Factory default
value of the phase seqvence function is OFF This function
should be selected ON if we request that the device warns the
user in case of false phase sequence The phase sequence
function is canceled when selected OFF.
Note: You pay attention that the output relay
2 is commonly used both phase
sequence warning and low voltage and
frequency warnings
kV
kV
kV
V
V
H
L
H
L
H
L
L-L
L-N
Hz
EVM-05C
VOLTAGE
MONITORING
H
L
True RMS
kV
kV
V
V
H
L
H
L
H
L
L-L
L-N
Hz
EVM-05C
VOLTAGE
MONITORING
H
L
True RMS
L1
L2
L3
V
L-L
V
L-N
H
kV
L
H
kV
L
H
kV
L
H
Hz
L
OUTPUT 1
OUTPUT 2
kV
kV
V
V
H
L
H
L
H
L
L-L
L-N
Hz
EVM-05C
VOLTAGE
MONITORING
H
L
True RMS
L1
L2
L3
V
L-L
V
L-N
H
kV
L
H
kV
L
H
(If you set 3rd
kV
L
Hz
H
L
OUTPUT 1
OUTPUT 2
L1
L2
L3
V
L-L
V
L-N
H
kV
L
H
kV
L
H
L2
L3
L1
kV
L
Hz
H
L
SET
OUTPUT 1
OUTPUT 2
ESC
ACTIVATING PHASE SEQUENCE FUNCTION
SET
L2
L3
L1
kV
SET
SET
ESC
VOLTAGE
MONITORING
EVM-05C
True RMS
SET
SET
ESC
SET
ESC
L2
L3
L1
kV
SET
SET
ESC
VOLTAGE
MONITORING
EVM-05C
True RMS
SET
ESC
ACTIVATING LATCH FUNCTION
SET
SET
SET
SET
VOLTAGE
MONITORING
EVM-05C
True RMS
ESC
SET
ESC
SET
6
Press SET button for 3 secs.
Find SP menu by scrolling UP/DOWN buttons.
Press SET
button.(SP Hi is
kV
displayed.)
V
V
H
L
L-L
L-N
Find PHS SEQ
Hz
menu by scrolling
UP/DOWN
H
L
buttons.
Press SET button.(PHS SEQ of
is displayed.)
In order to activate phase
sequence function:select ON
by scrolling UP/DOWN
buttons.
Press SET button(PHS SEQ is displayed.)
Press ESC button one by one until SAU SEt yES is
displayed.
Press SET button while SAU SEt yES is displayed.
LATCH FUNCTION
Latch function is used to control the output relays when
the voltage and frequency value return to the normal
value.It can be selected ON or OFF.
At position OFF:If the voltage and frequency value return
to the normal values,output relays release automatically.
At position ON:Even if the voltage and frequency value
return to the normal values,output relays remain
locked.The output relays release by pressing these
buttons
at the same time.
Press SET button for 3 secs.
Find SP menu by
scrolling
kV
UP/DOWN
buttons.
V
V
H
L
L-L
L-N
Hz
Press SET
button.(SP Hi is
H
L
displayed.)
Find LATCH menu by scrolling UP/DOWN buttons.
Press SET button.(LATCH of is displayed.)
In order to activate latch
function, select ON by scrolling
UP/DOWN buttons.
Press SET button(LATCH is
displayed.)
Press ESC button one by one until SAU SEt yES is
displayed.
Press SET button while SAU SEt yES is displayed.
L2
L3
L1
kV
kV
H
L
H
L
SET
EVM-05C
ESC
VOLTAGE
MONITORING
True RMS
L1
L2
L3
V
L-L
V
L-N
VOLTAGE
H
MONITORING
kV
L
EVM-05C
True RMS
H
kV
L
H
kV
L
SET
H
Hz
L
ESC
OUTPUT 1
OUTPUT 2
L2
L3
L1
kV
kV
H
L
H
L
SET
EVM-05C
ESC
VOLTAGE
MONITORING
True RMS
L1
L2
L3
V
L-L
V
L-N
VOLTAGE
H
MONITORING
kV
L
EVM-05C
True RMS
H
kV
L
H
kV
L
SET
H
Hz
L
ESC
OUTPUT 1
OUTPUT 2
Need help?
Do you have a question about the EVM-05C and is the answer not in the manual?