Specification; Part Description - Sealey AB3412 Quick Start Manual

340,000btu/hr space warmer® kerosene/diesel heater with wheels

Advertisement

DO NOT unplug the heater to switch it off. Use the ON/OFF switch.
8
WARNING! Improper maintenance can lead to poor combustion and soot production
NOTE:
This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they DO NOT play with the appliance.
Unplug the heater before moving it. Never pull the cable to unplug or move the unit.
9
DO NOT leave the heater unattended when in use.
8
Never use the appliance with wet hands or when either the heater or the power cable is wet.
8
If the supply cable is damaged, it must be replaced by the manufacturer, by a service agent or a similar qualified person.
9
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that may
occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but
must be applied by the operator.
2. INTRODUCTION
340,000Btu/hr (100kW) Heat output. Ideal for heating large well ventilated areas. Clean burning. Fitted with thermostat and digital room
temperature display both given in °C. Equipped with Danfoss oil nozzle and gear pump for stable fuel delivery, can operate with either kerosene
or diesel. Features automatic cut-out when oil is drained and non-automatic restart after power supply is interrupted. Easy-to-read fuel tank
gauge. Complies with rigorous standards.

3. SPECIFICATION

Model No:................................................................. AB3412
Airflow: ....................................................................... 765cfm
Automatic Shut-Off: .......................................................... Yes
Fuel Tank: ........................................................................ 68L
Fuel: ............................................................. Kerosene/Diesel
Heated Area: ............................................................. 2,000m³
Output: ............................................... 340,000Btu/hr(100kW)
Running Time per Filling (Maximum): ................................7hr
Supply: ................................................................. 230V - 13A
Transport Wheels: ............................................................ Yes
4. CONTENTS
Remove the heater from its carton. If the unit is in anyway damaged,
DO NOT use it and contact your supplier.
The following accessories are supplied in the shipping carton.
Part
Description
A
Handle
B
Feet pipe
C
Nut M5
D
Plain washer
E
Spring washer
F
Screw
G
Nut M12
H
Plain washer ø12
I
Wheel
J
Cotter
K
Wheel shaft
5. ASSEMBLY
5.1.
Insert the wheel shaft K to the corresponding hole of feet pipe B, insert the cotter J to the corresponding holes; slide the wheel I over
the wheel shaft K put plain washer H to the two sides of shaft, screw the nut G to fix the wheel on the shaft.
5.2.
Put the heater body on the feet pipe assembly, make sure the 4 holes of handle A point towards the corresponding 4 holes on the
feet pipe respectively.
5.3.
Using the screw F ,spring washer E, plain washer D and nut C to fix the feet pipe assembly and handle to the tank.
© Jack Sealey Limited
QTY
1
1
12
12
8
12
2
2
2
2
1
Original Language Version
fig.1
AB3412 Issue 2 (3) 03/02/2021