Ef1: Drain Hose Blocked/Kinked/Too High; Drain Filter Clogged/Dirty; Ef2: Excessive Detergent Dosing; Drain Hose Kinked/Blocked; Drain Filter Dirty/Clogged; Ef3: Aqua Control Device Triggered; Ef4: Water Fill Pressure Too Low And Solenoid Valve Open - Electrolux EWM10931 Service Manual

Table of Contents

Advertisement

EF1

EF1: Drain hose blocked/kinked/too high; drain filter clogged/dirty

Checks to perform:
This warning only appears at the end of the cycle. The appliance detected long drainage phases during
the cycle. (E.g.: More than 20 seconds when draining after rinses). Check/clean the drain filter.
EF2: Excessive detergent dosing; drain hose kinked/blocked; drain
EF2
Checks to perform:
This is an excessive detergent dosing warning. The system detected too much foam was forming during
the drain phases. Advise the Customer to use the correct quantity of detergent and to make sure the
EF3
Checks to perform:
This warns about the presence of water at the bottom of the appliance. Check for any water leaks
Or caused by excessive overheating of the drain pump. Check for any items which may obstruct

EF4: Water fill pressure too low and solenoid valve open

EF4
Checks to perform:
It is a warning that the water pressure is too low. If the water pressure is connect, check:
EF5
Checks to perform:
This is an unbalanced load warning. The appliance detected an extremely unbalanced load during the
spin phases. Advise the customer to load more washing into the drum and not just individual garments.
2011 SOE/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics of electronic controls EWM10931
filter dirty/clogged
filter and drain circuit are clean.

EF3: Aqua Control device triggered

and that the Aqua Control device float is positioned correctly.
the normal operation of the rotor.
the wiring of the flowmeter and the Flowmeter.

EF5: Unbalanced load, spin phases skipped.

!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
67/75
If there are burns on the circuit
board, see page 73
599 73 77-37
EF1
EF2
EF3
EF4
EF5

Advertisement