Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C,
with relative humidity at 0 % to 90 %.
Extended specifications are available at www.fluke.com.
Maximum voltage between any terminal and earth ground........................600 V
Display
Digital .........................................................................................................................6000 counts, updates 4/s
Bar Graph ..................................................................................................................33 segments, updates 32/s
Temperature
Operating..................................................................................................................-10 °C to 50 °C
Storage......................................................................................................................-40 °C to 60 °C
Temperature Coefficient .........................................................................................0.1 x (specified accuracy)/°C
Altitude
Operating..................................................................................................................2000 meters
Storage......................................................................................................................10 000 meters
Relative Humidity.......................................................................................................95 % to 30 °C, 75 % to 40 °C, 45 % to 50 °C
Battery...........................................................................................................................IEC 6LR61
Battery Life ..................................................................................................................400 hours typical, without backlight
Safety ............................................................................................................................IEC 61010-1: Pollution Degree 2
Ingress Protection.....................................................................................................IEC 60529: IP42 (non-operating)
Electromagnetic Compatibility (EMC)
International ................................................................................................................IEC 61326-1: Portable Electromagnetic
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy
that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected
to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be
potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and
radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate
protection to radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test
object.
Korea (KCC) ..............................................................................................................Class A Equipment (Industrial Broadcasting &
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user
should take notice of it. This equipment is intended for use in business environments and not to be used in
homes.
USA (FCC) .................................................................................................................47 CFR 15 subpart B. This product is
True-rms Multimeter
(<18 °C or >28 °C)
IEC 61010-2-033
Measurement CAT III 600 V
Environment CISPR 11: Group 1, Class A
Communication Equipment)
considered an exempt device per clause
15.103.