Accessories; Specifications - Fluke 802CN User Manual

Vibration meter
Table of Contents

Advertisement

802CN/802-II
Users Manual

Accessories

Table 1
is a list of the accessories available for the Product.
Table 1. Accessories
Description
Soft case
Battery door
Bottom cap

Specifications

Built-in Piezoelectric Accelerometer
Sensitivity (typical) ..................... 10.00 mV / m/s² ±5 %
Measurement
Acceleration
Range. ......................................... 0.1 m/s² to 199.9 m/s²
Resolution.................................. 0.1 m/s²
Accuracy .................................... ±(5 % + 2 digits)
2
PN
4106625
4684258
4684264
(1 g = 9.8 m/s²)
rms
2
(
)
Peak
(LO: 10 Hz to 1 kHz)
±(10 % + 5 digits)
(HI: 1 kHz to 10 kHz)
Velocity
Range .......................................... 0.1 mm/s to 199.9 mm/s rms
Resolution.................................. 0.1 mm/s
Accuracy .................................... ±(5 % +2 digits) (10 Hz to 1 kHz)
Displacement
Range .......................................... 0.001 mm to 1.999 mm Peak-
Resolution.................................. 0.001 mm
Accuracy ................................... ±(5 % +2 digits) (10 Hz to 1 kHz)
Piezoelectric Accelerometer
Typical
Frequency Response ........... 10 Hz to 15 kHz
rms 2 2
(
)
Peak
hyt011.jpg