Regulatory Sign

The regulatory sign, which is a 12V system for Plus
within the signal head to which the Regulatory Sign is mounted. An individual RAG node provides
an interface for one or two Regulatory Signs. The connection(s) is made directly to PL5 on the RAG
node, as per
Figure 51
below.
If further Regulatory Signs are required then an addition RAG node will be required, which will be
fitted in the Amber or Red Aspect chamber.
Second Regulator Sign Position
Yellow (+12V) – Pin 2
Grey (0V) – Pin 4
4.8.1
Installing Three Regulatory Signs
If three Regulatory Signs are required to be mounted (powered) on/by a single Traffic Signal Head,
an additional RAG node will be required. This second RAG node will need to be mounted behind
the Amber aspect.
4.8.2
Parts
Plus+ HELIOS Side Mounted Regulatory Body
Plus+ HELIOS In Line Mounted Regulatory Body 667/1/53500/808
HELIOS Regulatory Sign Door Assembly 667/1/30200/XXX
Plus+ HELIOS Regulatory Internal Illumination Assembly 667/1/53514/000
ST950 Plus+ User Manual
+
Figure 51 : Reg Sign Connected to RAG Node
667/1/53500/807