Commissioning - Bosch Rexroth RE 07601-B Operating Instructions Manual

Manifolds and modules
Table of Contents

Advertisement

8

Commissioning

Incorrectly mounted manifold/module!
A powerful fluid jet may leak at incompletely mounted hydraulic connections and
connection lines and cause serious injuries.
Only commission your system after all hydraulic connections and the manifold
and/or the module have been completely and properly mounted according to
the specifications.
Look out for defective sealing points and exchange defective seal rings
immediately.
Wear personal protective equipment during the initial commissioning.
Inadmissibly high operating pressure!
Thus, the manifolds and/or the modules may burst or the closing elements may fly
around and cause serious injuries.
Before commissioning the hydraulic system, ensure that the maximum admis-
sible pressure of the hydraulic components in the system is not exceeded by
no means.
Ensure that in your system, the maximum admissible operating pressure is se-
cured by means of pressure limitation equipment.
Uncontrolled connection or disconnection of plug-in connectors!
Electric components may be damaged.
Before installation works, separate the device from the mains or from the
voltage source or de-energize it.
Do not plug in or pull the electric plug-in connector as long as the voltage supply
is activated.
Make sure that all hydraulic connections are covered and all electrical connec-
tions are allocated.
Immediately depressurize the system if hydraulic fluid still leaks despite prop-
er assembly.
Commission hydraulic components only if they are completely installed.
Allow manifolds/modules with integrated electronics to acclimatize for some time
prior to commissioning as the electronics might be damaged by the generation of
condensed water.
Electrical connections must be checked for proper condition by or under the
guidance and supervision of a specialized electrician before the initial or any
re-commissioning.
Check before switch-on whether the protective earthing conductor at all electric
devices is firmly connected according to the connection diagram.