Download Print this page

Spectra T50e Service Quick Reference Manual

Hide thumbs Also See for T50e:

Advertisement

Quick Links

Service Procedure Quick Reference
LCM Replacement
T50e
Tools & Supplies
Estimated Time
ESD Protection
Library Power
Data I/O Operations:
Robotic Movement
Admin./Superuser
BlueScale Login
Considerations
Not a substitute for official published procedural guide
Detailed instructions/videos located at support.spectralogic.com
Replacement T50e LCM module
#2 Phillips screwdriver
USB flash drive (FAT32)
o With saved library configuration and/or MLM/DLM database – if available
o For collecting Auto-support Log File (ASL)
20 minutes
Required
Off
Discontinue
Verify with customer that data I/O to all drives has halted
Discontinue
Verify robotic movement has halted
Verify with customer that move requests from host have been halted
Required
It is recommended that all tapes are removed from drives by customer before
procedure to avoid potential stuck tapes after power-up
Verify customer has a current backup
o Library configuration
o MLM and DLM databases
o Encryption keys
*
Due to high probability for corruption, it is not recommended to attempt backup of
library configuration, MLM/DLM database or encryption keys if LCM is malfunctioning
Refer to "Spectra T50e Library Control Module Replacement Instructions"
service guide for information that should be documented/backed-up by
customer prior to service
*
of the following (if applicable):
August 2017 V2
Page 1 of 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the T50e and is the answer not in the manual?

Questions and answers

Summary of Contents for Spectra T50e

  • Page 1 Due to high probability for corruption, it is not recommended to attempt backup of library configuration, MLM/DLM database or encryption keys if LCM is malfunctioning  Refer to “Spectra T50e Library Control Module Replacement Instructions” service guide for information that should be documented/backed-up by customer prior to service...
  • Page 2 11. If previously saved library configuration is not available, customer must manually reconfigure library (reference T50e User Manual) 12. Create an Auto-support Log File (ASL) and forward to Spectra Technical Support  Obtain permission from customer prior to performing this step ...
  • Page 3 Not a substitute for official published procedural guide Detailed instructions/videos located at support.spectralogic.com Service Procedure Quick Reference LCM Replacement T50e 13. Host backup processes can resume normal operation 14. Package the old LCM and return it to Spectra Logic August 2017 V2 Page 3 of 3...