5.2.7.4. Active/Reactive Power Control

A password is required to enter Acitve/Reactive Power Control page.
This page includes two kinds of function: active power control and reactive
power control. In active power control function, there are 3 control modes:
Power Limit, Power vs. Frequency, and P(V). In reactive power control
function, there are 4 control modes: Constant cosphi, cosphi(P),
Constant Q, and Q(V).
Only some of countries (electricity regulations) have the requirement of
these functions.
Settings
21. Jun 2010 13:50
Personal Settings
Coefficients Settings
Install Settings
Active/Reactive Power Control
FRT
5.2.7.4.1. Active Power Control – Power Limit
This control mode can reduce the output power to a percentage of
inverter's rated power. Users can limit the output power by set the Set
Point in Power Limit page.
Active/Reactive Power
Power Limit
Power vs. Frequency
P(V)
Password
ENT
*
EXIT
Figure 5-14 Active/Reactive power setting page
21. Jun 2010 13:50
Figure 5-15 Power limit setting page
21. Jun 2010 13:50
ENT
ENT
EXIT
Active Power Control
Set Point
ENT
Actual/Rated Power
Mode
EXIT
31
Turn on/off PV inverter
Active/Reactive Power
21. Jun 2010 13:50
Active Power Control
Reactive Power Control
21. Jun 2010 13:50
[
100
[
Rated
[
OFF
]
%
]
]