7.5 Injection Pump / HP Pump

7.5.1 HP pump – Filling with engine oil
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Engine oil
WARNING
Fuels are combustible.
Risk of fire and explosion!
• Avoid open flames, electrical sparks and ignition sources.
• Do not smoke.
WARNING
Oils/oil vapors are combustible.
Risk of fire!
• No open flames, no electric sparks. Do not smoke. Avoid ignition sources.
CAUTION
Fuel system high-pressure pump not filled with engine oil.
Damage to components, major material damage!
• Make sure that the high-pressure fuel pump is filled with engine oil before installation or initial
operation.
Filling HP pump
1.
Fill fresh engine oil into a clean receptacle.
2.
Fill HP pump (1) at connection (2).
Part No.