Reference Sections; A Environment For Storage, Transportation And Stationary Use - ABB ACS 160 User Manual

Driveit low voltage ac drives
Table of Contents

Advertisement

Reference Sections

A Environment for Storage, Transportation and Stationary Use

ACS 160
Installation Site Altitude
Ambient Temperature
Contamination Levels
(IEC 721-3-3)
Sinusoidal Vibration
nd
(IEC-721-3-3, 2
edition
1994-12)
Shock
nd
(IEC-721-3-3, 2
edition
1994-12)
Free Fall
6
Stationary Use
• 0...1000 m (0...3300 ft) if P
and I
100%
2
• 1000...2000 m (3300...6600 ft)
if P
and I
derated 1% every
N
2
100 m (330 ft) above 1000 m
(3300 ft)
• -10...40 ° C (14...104 ° F) in
motor mounting
• 0...40 ° C (32...104 ° F) in wall
mounting
• max. 50 ° C (122 ° F) with
derating. See P.
According to IP65 classification
• chemical gases: Class 3C3
• solid particles: Class 3S3
In motor mounting:
• 2-9 Hz max amplitude 3 mm
(0.118 in)
• 9-200 Hz max acceleration
2
2
10 m/s
(33 ft/s
)
In wall mounting:
• 2-9 Hz max amplitude 1.5 mm
(0.06 in)
• 9-200 Hz max acceleration
2
2
5 m/s
(16 ft/s
)
In motor mounting:
2
• max 250 m/s
(820 ft/s
In wall mounting:
2
• max 70 m/s
(230 ft/s
not allowed
Storage and Transportation
in the protective package
-
N
-40...+70 ° C (-40...+158 ° F)
Storage
• chemical gases: Class 1C2
• solid particles: Class 1S3
Transportation
• chemical gases: Class 2C2
• solid particles: Class 2S2
• max. 300 m/s
2
), 6 ms
2
), 11 ms
• 76 cm (30 in.), according to ISTA 1A
2
2
(985 ft/s
), 18 ms
ACS 160 User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents