Recall For Analog Telephones - NEC SL1000 Getting Started Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000 Getting Started Guide
200
201
202
203
204
205
206
207

Recall for Analog Telephones

You may want to change this setting if:
You have Analog telephones connected and the RECALL key does not work correctly. This is
highlighted when you press the RECALL key but the call is not placed on hold.
The RECALL is also referred to as Timed Break Recall (TBR).
System Operation:
The SL1000 must be configured with the correct RECALL timing that matches the Analog telephones that you
have connected.
Program82-04-0x
Set the system to detect a RECALL duration of 105ms to 1000ms. You will need to change three options within
this program.
Default Setting:
The SL1000 will accept a RECALL duration of 540mS to 660mS(600ms±10%).
1. After Log-In to the Programming Mode.
If you already Log-In the programming mode, skip this operation.
2. Dial 82 04 04, Enter the Maximum Break Time (default: 100ms (20) )
and Press Hold key 3 times to confirm the entry and step to the next
option.
3. Change the setting to 21 (this is equivalent to 105mS) and Press Hold
key to confirm the entry and step to the next option.
4. Change the setting to 200 (this is equivalent to 1000mS) and Press
Hold key to confirm the entry and step to the next option.
5. Press Mute key several times when you are done to return to the
Program Mode.
6. Press Speaker key to save changes and exit if you are finished.
Configuration Sheet: RECALL Timing
With defaults shown.
82-04-04
default=20
(100mS)
Setting
Equivalent
duration (mS)
Operation
82-04-07
82-04-08
default=108
default=132
(540mS)
(660mS)
39
Display shows;
Program Mode
82-04-04
Max.Break TM 20
82-04-07
Min.Flash TM 21
82-04-08
Max.Flash TM 200

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip4ww-1632m-a ksu

Table of Contents