  • Page 1 Sliding gate operator FA01229-EN BKS22TLS EN English INSTALLATION MANUAL...
  • Page 3 Before continuing, also read the general precautions for users. Employ this product only for the use for which it was expressly made. Any other use is dangerous. Came S.p.A is not liable for any damage caused by improper, wrongful and unreasonable use • The product covered by this manual is defi ned in accordance with the Machinery Directive 2006/42/EC as a "partly completed machinery".
  • Page 4 INTENDED USE The gearmotor is designed to power sliding gates used in apartment blocks and industrial plants. INTENDED USE Model BKS22TLS Standard reference* length of the sliding part (m) 10 series Maximum weight of the sliding part (kg) 2,200 series...
  • Page 5 DUTY CYCLES Datum Cycles/hour (no.) 14 series Consecutive cycles (no.) 17 series The cycles calculation is for standard-length gates (see the intended use), that are professionally installed, free of any mechanical issues and/or accidental friction points, and measured at 20° C, as stated in EN Standard 60335-2-103. DESCRIPTION OF PARTS 1.
  • Page 6 GENERAL INSTALLATION INDICATIONS ⚠ Only skilled, qualified staff must install this product in full compliance with the law in force. PRELIMINARY CHECKS ⚠  Before installing the gearmotor it is necessary to: • check that the upper slide-guides are friction-free; • check that the gate is stable and that the casters are in good working order and lubricated; •...
  • Page 7 FITTING THE ANCHORING PLATE Set up a foundation frame that is larger than the anchoring plate and sink it into the dug hole. The foundation frame must jut out by 50 mm above ground level. Fit an iron cage into the foundation frame to reinforce the concrete. Fit the bolts into the anchoring plate ❶ ...
  • Page 8 Remove the foundation frame and fill the hole with earth around the concrete block. Remove the nuts from the bolts. Fit the electric cables into the tubes so that they come out about 600 mm. PREPARING THE GEARMOTOR Remove the front cover and the gearmotor cover.
  • Page 9 Place the gearmotor above the anchoring plate. Caution! The electrical cables must run under the gearmotor casing and must not touch any parts, such as the motor, transformer, and so on - that heat up during operation. Raise the gearmotor by 5 to 10 mm from the plate by turning the threaded feet, to make room for further pinion and rack adjustments. FASTENING THE RACK If the rack is already set up, the next step should be to adjust the rack-and-pinion coupling distance, otherwise, fasten it: - release the gearmotor...
  • Page 10 ADJUSTING THE PINION-RACK PAIRING Manually open and close the gate and adjust the pinion-rack coupling distance using the threaded feet (vertical adjustment) and the holes (horizontal adjustment). This prevents the gate's weight from bearing down on the gearmotor. FASTENING THE GEARMOTOR Once adjusting is complete, fasten the gearmotor to the plate using the plates and nuts.
  • Page 11 ESTABLISHING THE LIMIT-SWITCH POINTS For opening: - open the gate ❶ - fi t the opening limit-switch tab onto the rack until the micro switch activates (spring) and fasten it using the grub screws ❷ ❸ Spring ~ 20 mm For closing: - close the gate ❹...
  • Page 12 CONNECTING THE GEARMOTOR AND THE LIMIT SWITCH - Open the protection box ; - Drill the protective box and run through it the cables from the external panel . Gearmotor-limit switch assembly already connected for installation on the left inside view. E1 EX ZT6/ZT6C FC FA F...
  • Page 13 CHANGES ON ELECTRICAL CONNECTIONS FOR GEARMOTOR INSTALLATION ON THE RIGHT For installing on the right: - reverse the limit switch FA-FC on the terminal board; - reverse the U-V phases of the motor on the terminal board. ZT6/ZT6C FC FA F E1 EX 400V (AC) 230V (AC)
  • Page 14: Final Operations

    ☞  CAME CANCELLI AUTOMATICI S.p.A. employs a certified Environmental Management System at its premises, compliant with the UNI EN ISO 14001 standard to ensure the environment is safeguarded. Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply follow these brief disposal guidelines:...