REVIEWING THE TRACER 4106/4206 REAR PANEL DESIGN

Figure 2 identifies the various features of the TRACER 4106/4206 rear panel and Table 1 on page 26
provides a brief description of each interface.
A
RS232 Interface
(VT100 Terminal)
T1A
B
Test
T1 Interfaces
612804206L2-1A
Table 2. TRACER 4106/4206 LEDs
This color light...
Indicates that...
Green (solid)
the TRACER 4106/4206 is connected to a power source.
Off
the TRACER 4106/4206 is not currently powered up.
Green (solid)
the TRACER 4106/4206 is transmitting on Frequency Plan A.
the TRACER 4106/4206 is not transmitting on Frequency
Off
Plan A.
Green (solid)
the TRACER 4106/4206 is transmitting on Frequency Plan B.
the TRACER 4106/4206 is not transmitting on Frequency
Off
Plan B.
there is a communication problem between the local and remote
Red (solid)
TRACER 4106/4206 systems.
there is an Alarm Condition on a T1 Interface. Check the
Red (solid)
respective T1 status page to identify the active alarm.
Red (blinking)
the respective T1 is in a loopback mode.
Red (solid)
the RSSI level is approaching 0 Volts of RSSI.
Amber (solid)
there is an active test being performed by the system.
T1B
T1C
T1D
C
Alarm
Contacts
Figure 2. TRACER 4106/4206 Rear Panel
© 2004 ADTRAN, Inc.
Section 3 Engineering Guidelines
E
DC Power
Connection
F
D
Fuse
G
Antenna
Connector
H
Ground
Lug